B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fi re.
Note: For non-combustible fi replace fi nish mate-
rial (marble, stone, etc) specifi cations refer to Figure
13.13 and Figure 13.15.
Combustible Mantels
1/2 in.
Thick Wall
Sheathing
14 in.
MIN.
Figure 13.8 Clearances To Combustibles Mantels Or Other
Combustibles Above Appliance
Non-combustible Mantels
1/2 in.
Thick Wall
Sheathing
14 in.
MIN.
Figure 13.9 Clearances To Non-Combustible Mantels Or Other
Non-Combustibles Above Appliance
12 in.
MAX.
MEASUREMENT FROM TOP OF
FIREPLACE OPENING
12 in.
MAX.
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Heat & Glo • SLR • 2143-900 Rev. D • 12/08
Combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
Figure 13.10 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
Non-combustible Mantel Legs Or Wall Projections
Extending Past The Face Of The Fireplace
Figure 13.11 Non-Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
2 IN.
3 FT. MAXIMUM
MINIMUM
6 IN.
MINIMUM
3 IN.
UNLIMITED
MINIMUM
51