INSTALLATION IN CANADA
MASONRY and HEAT-CIRCULATING
(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE
PROHIBITED IN CANADA)
Whether installed in a masonry or heat-circulating fire-
place, this fireplace insert must be installed with a continu-
ous chimney liner of 6 inches (152mm) diameter extending
from the fireplace insert to the top of the chimney. The
chimney liner must conform to the Class  requirements
of CAN/ULC-S65, Standard for Lining Systems for Exist-
ing Masonry or Factory-Built Chimneys and Vents, or CAN/
ULC-S640, Standard for Lining Systems for New Masonry
Chimneys.
• Do not remove bricks or mortar from fireplace to
accommodate insert.
• To prevent room air passage to the chimney cavity of
the fireplace seal the damper area around the chimney
liner with high temperature sealant.
• The permanent metal warning label provided must be
affixed to the back of the fireplace with screws or nails
to the fireplace, in a location readily visible should the
fireplace insert by removed, stating that the fireplace
may have been altered to accommodate the insert, and
must be returned to original condition for use as a con-
ventional fireplace
NOTE:
In Canada when using a factory-built chimney it must be
safety listed, Type UL 10 HT CLASS "A" or conforming
to CAN/ULC-S629, STANDARD FOR 650°C FACTORY-
BUILT CHIMNEYS.

DOOR HANDLE ASSEMBLY

1. Install washer on door handle shaft.
2. Slide door handle through door.
. Install second washer(s) as shown.
4. Install key in groove.
5. Align groove in latch cam with key; slide latch cam over
shaft.
6. Install locknut.
7. Install spring handle turning counter-clockwise to
desired location on handle.
CAUTION
• Do NOT overtighten lock nut.
• Door handle needs to move smoothly.
September 1, 2008

LEVELING LEGS

1. Remove the 2 screws already installed on each leg.
2. Move legs to the desired height.
. Re-install the screws to secure in place.
Figure 11.1
Latch Cam
Locknut
Figure 11.2
7007-161H
2700-I WOOD INSERT (ACT)
Door Cross Section
(example)
Door Handle
Spacing
Washers
Square Key
Spring
Handle