Canadian Masonry & Heat Circulating; Leveling Bolts And Sheet Metal Shims - Quadra-Fire 4100I-GD-B Manual

Wood insert advanced combustion technology (act)
Hide thumbs Also See for 4100I-GD-B:
Table of Contents

Advertisement

R
(INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA)
Whether installed in a masonry or heat-circulating fi replace, this fi replace insert must be installed with a continuous chim-
ney liner of six inch (152mm) diameter extending from the fi replace insert to the top of the chimney. The chimney liner must
conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry
Chimneys and Vents, or CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
• Do not remove bricks or mortar from fi replace to accommodate insert.
• The face of the fi replace must be sealed to prevent room air passage into the chimney cavity.
• The permanent metal warning label provided must be affi xed to the back of the fi replace with screws or nails to
the fi replace, in a location readily visible should the fi replace insert by removed, stating that the fi replace may
have been altered to accommodate the insert, and must be returned to original condition for use as a conven-
tional fi replace.
• Circulating air chambers may not be blocked.

LEVELING BOLTS AND SHEET METAL SHIMS

Reach between side of insert and outer skin
Figure 12A
SHEET METAL GUIDES
Slide each guide under the insert on each side placing
them directly under leveling bolts. If they are not directly
under the bolts, the bolts may hang up on uneven material
when sliding the insert into place. See Figure 12B.
Page 12
4100-I ACT WOOD INSERT
INSTALLATION IN CANADA
MASONRY and HEAT-CIRCULATING
cut-out view
Leveling Bolt
250-7201 Rev D
This product shipped with two leveling bolts, and two sheet
metal guides for ease in sliding the insert into place when
using the leveling bolts. Not all installations will require the
use of the leveling bolts. The sheet metal guides are used
only when the leveling bolts are necessary. Discard if not
needed.
ADJUSTING THE LEVELING BOLTS
It is best to use a 1/2 inch (12.7mm) socket wrench with an
extended handle for ease in adjusting bolts to the desired
level. The bolts will adjust from 0 to 2 inches (0 - 51mm).
You can also reach in and adjust the bolts by hand, although
space is limited. Figure 12A.
Sheet Metal Shims
Place under leveling bolts
and slide insert into place
Figure 12B
or Factory-Built
Leveling Bolts
March 27, 2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4100i-nl-b4100-i act

Table of Contents