C. Sidewalls/Surrounds
Adjacent combustible sidewalls must be located a minimum 24 in. (610 mm) from the fi replace opening.
Combustible and noncombustible mantel legs, surrounds and stub walls may be constructed within the gridded area,
Figure 6.3.
FLUSH
FRONT
28 5/8 in.
[727 mm]
24 in.
[610 mm]
Figure 6.3
Mantel Leg or Wall Projections (Acceptable on both sides of opening)
D. Frame the Fireplace
Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.
Framing across the top of fi replace must be above top standoffs.
2 in. (51 mm)
min. air space
clearance
from chimney.
C
B
Figure 6.4
Framing the Fireplace
20
Note: Grid depicts 1-in scale.
A
B
Note: Framing must be
extended straight up,
all the way to the ceiling.
Header MUST NOT be notched!
D = extra space needed for outside air connection.
If outside air duct has no bend, this dimension may be
reduced as long as minimum clearances are met.
D
A
Heatilator • I60, I80 • 4013-250 • Rev C • 11/08
4 in.
BRICK
[102 mm]
FRONT
19 3/4 in.
[502 mm]
24 in.
[610 mm]
Model
A
in.
45 1/2
I60
mm
1156
in.
51 1/2
I80
mm
1308
* If interior of chase will be drywalled, add the thickness to
this measurement.
** Adjust header height for a raised fl oor under fi replace.
Model
A
inches
36
I60
mm
914
inches
42
I80
mm
1067
D
B*
C**
(4" duct)
28
50
8
711
1270
203
28 1/2
50
8
724
1270
203
B
45
1130
50 1/2
1283
D
(6" duct)
12
305
12
305

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I80

Table of Contents