6
Gas Information
A. Fuel Conversions
Before making gas connections ensure that the appliance
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies specified
and approved parts.
1. Converting to LP Gas
NOTE: Gas conversions should only be performed
by a qualified service person, and/or where required
by state and local codes, licensed installer/service
technician. In the Commonwealth of Massachusetts,
installation must be performed by a licensed plumber
or gas fitter.
KIT CONTENTS: Replacement orifice; replacement pilot
injector; valve regulator; conversion label.
TOOLS REQUIRED: Power drill (a 90° drill is helpful);
Slotted screwdriver or Torx TH20; #2 Phillips bit; 5/32"
Allen wrench; 3/8" open end wrench.
Remove 2 screws
Lift off the appliance top and place it on a flat sur-
Figure 6.1
face, with the porcelain side up to prevent damage. Remove
the appliance front by sliding it upwards in the grooves, being
careful not to chip the porcelain. Lay the appliance front face
up on a flat surface.
Remove burner: First remove ONLY the two screws indi-
cated in. DO NOT remove the screws from the burner top.
Lift the burner up and out of the firebox.
September 1, 2008
Figure 6.2
remove the wire clip.
Figure 6.3
injector.
Replace pilot injector with the appropriate size injector supplied
with the appliance (#35 for Propane, #62 for Natural Gas).
Replace pilot hood, snapping into position. Be sure to align
notch on left side of pilot hood.
Figure 6.4
Replace orifice with the proper size as indicated below for
your gas type and venting.
Reinstall burner.
Quadra-Fire · Garnet-T · 7016-127F
PILOT HOOD
MILLIVOT GENERATOR
THERMOCOUPLE
Pull off pilot hood and set aside. NOTE: Do not
Use a 5/32 in. Allen wrench to remove the pilot
Remove main burner orifice using a 3/8 in. wrench.
PROPANE
NATURAL GAS
#56
5/32 in. Allen
wrench
#49
Page 25