Ignition Module Access And Battery; Replacement; Intake Damper Operation; Shutter Adjustment - Quadra-Fire Direct Vent Room Heater GARNET-D-CSB Owner's Manual

Garnet-t direct vent room heater
Table of Contents

Advertisement

I. Ignition Module Access and Battery

Replacement

The ignition module is located under the appliance
Figure 8.16
attached to the decorative cover.
Lift off the appliance top and place it on a flat surface, with
the porcelain side up to prevent damage.
Remove the appliance front by sliding it upwards in the
grooves, being careful not to chip the porcelain. Lay the
appliance front face up on a flat surface.
With the cast iron front of the appliance removed, remove the
decorative cover located under the appliance. To remove the
cover, remove the two screws on the front of the appliance
that hold the cover in place. Pull the cover forward, down
and out. The module will then be accessible for service or
battery replacement.
The single "AA" 1.5V battery that powers the ignitor is
located in the module. To replace the battery, open the
battery compartment and remove the old battery. Replace
the battery making sure the polarity is correct.
J. Intake Damper Operation
The intake damper can be used with or without the flue restric-
tor to adjust the air flow. Opening the damper makes the
flames shorter and more active. Closing the damper makes
the flames taller and less active.
Page 36
Figure 8.17
wingnut is located on the underside of the appliance, to the
right of the pilot assembly.
To CLOSE the intake damper, pull the wingnut forward toward
the front of the appliance..
To OPEN the damper, push the wingnut back. Adust the
damper in 1/4 in. increments until the desired flame is
achieved. After adjustment, tighten the nut.
K. Shutter Adjustment
Figure 8.18
appliance, on the right side. To adjust the shutter, loosen
the wingnut.. Retighten the wingnut after adjustment.
Moving the shutter bolt to the right closes the shutter. Moving
the shutter bolt to the left, will open the shutter. Opening the
shutter causes flames to become shorter and blue. Closing
the shutter creates taller orange/yellow flames.
NOTE: Do not close so much as to cause a sooty flame.
Improper adjustment can cause sooting in the firebox and/
or on the outside of a house with a horizontal termination.
After adjustment, tighten nut to lock in place.
Quadra-Fire · Garnet-T · 7016-127F
Loosen the wingnut that secures the damper. The
OPEN
The shutter is located on the underside of the
OPEN
CLOSE
CLOSE
September 1, 2008

Advertisement

Table of Contents
loading

Table of Contents