6-10 Drive Bay Installation/Removal

Accessing the Drive Bays

SAS/SATA Drives: You do not need to access the inside of the chassis or remove
power to replace or swap SAS/SATA drives. Proceed to the next step for instructions.
You must use standard 1" high, SAS/SATA drives in the system.
Note: Refer to Supermicro's web site for setup guidelines:
com/support/manuals/>.
The SC827 chassis contains four individual motherboards in separate node drawers
(Figure 6-14). Each motherboard node controls a set of three hard drives. Note that
if a motherboard node drawer is pulled out of the chassis, the hard drives associated
with that node will power down as well.
Motherboard Drawer Locations in the Chassis
Motherboard B
Controls HDDs B1, B2 and B3
Motherboard A
Controls HDDs A1, A2 and A3
Figure 6-14. Hard Drives and the Corresponding Motherboards