Mitsubishi Electric AG-150A Instruction Book page 5

Air-conditioner control system centralized controller
Hide thumbs Also See for AG-150A:
Table of Contents

Advertisement

Function
ON/OFF (system)
Operation status of each group
in the system
Filter sign
Water circuit sign
(Air To Water (PWFY))
Monitor
*1
Local operation prohibition
Error
Error history monitor
External output
Date and time
License
Unit Info.
Network
Operation
*1
Advanced
Groups
Blocks
Interlock
Floor Layout
Monitor
Refrigerant system
*1
configuration confirmation
Ext Temp Interlock
Operation
*1
Setback
Maintenance User
User Info
Building Manager
Copying data to a USB memory
drive
Data utility
Reading data from a USB
memory drive
Touch panel calibration
Connection/Interlock
Information
Error history
Schedule data
Data
Current time
back-up
Saving the data on a USB drive
Reading data from USB
memory
Screen lock function
Device
Touch panel cleaning
maintenance
Time synchronization
The ON/OFF indicator lamp (LED) indicates if one or more groups or all the groups in the
system are stopped.
Operation status (ON/OFF), operation mode, fan speed, temperature setting, air flow
direction, operation status (ON/OFF) of interlocked units is displayed.
Indicates that the filters on the units in a given group is due for cleaning.
Indicates that the circulating water circuit in a given group is due for replacement.
Displays the functions that the controller forbids or the functions that are forbidden by High-
level equipment.
The address of the unit in error, error code, and the address of the unit that detected the
error will appear.
Up to 384 errors can be stored in memory. (128 errors per AG-150A or Expansion controller
(64 unit errors, 64 communication errors))
Outputs signals (run/stop, error) to an external device. Requires an external input/output
adapter (sold separately).
This function is used to set the current date/time and daylight savings time.
This function is used to register license.
This function is used to set unit name, ID number, connection or non-connection of
Expansion controller, brightness of the LCD, sound volume, date format, time format,
temperature unit, and display language, test run availability, screen lock and room
temperature availability.
This function is used to set the IP address, subnet mask address, and gateway settings for
the LAN and also to set the address, K-transmission converter address, local control
prohibit settings, and external input settings for the M-NET; and the Expansion controller
settings.
Allows the Master/Sub clock setting to be made.
This function is used to register indoor units, LOSSNAY units , DIDO controller (PAC-
YG66DCA), Air To Water (PWFY), remote controllers, and lower-level system controllers to
a group.
This function is used to register a group to a block.
This function is used to interlock the operation of indoor units and LOSSNAY units.
This function is used to make the basic settings for the floor layout and display position of
the groups.
Allows the user to see which indoor units are connected to each outdoor unit.
Control level of outside temperature interlock function can be set for each group.
Control time and upper/lower limit temperature can be set for setback function.
Allows the maintenance user name and password to be set.
Allows the building manager name, password, function enable/disable settings to be made.
The setting data (Initial setting and user info) and the operation data (charge parameter and
electric energy data) can be copied to a USB memory drive.
The setting data (Initial setting and user info) can be read from a USB memory drive.
The touch position on the touch panel can be adjusted.
Group setting information and interlock setting information are retained, even if power is
turned off.
Retained, even if power is turned off.
Schedule information of each group is retained, even if power is turned off.
Current time is retained by the built-in capacitor for a week, even if power is turned off.
(It takes approximately a day to fully charge the built-in capacitor. There is no need to
replace the capacitor.)
The initial setting data, user info, and operational data (charge parameters, power
consumption) can be stored to a USB memory.
Initial setting data can be read from USB memory.
The screen can be locked to prevent access until a valid user name and password are
entered.
Touch panel is locked and can be cleaned.
Clocks on the controllers and units that are under the control of the main controller are
synchronized once a day (applicable only to the ones that support this function).
– 4 –
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag-150a-a

Table of Contents