Download Print this page

Technical Specifications - HP rp3000 Quickspecs

Point of sale (pos) system
Hide thumbs Also See for rp3000:

Advertisement

QuickSpecs

Technical Specifications

Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 20 mm clearance on front side and a 50 mm clearance on the rear side of the computer to permit the required airflow.
If within an enclosure, the front side should be 100% open. The clearance between the system and rear of the cabinet must be at
least 50 mm with power supply venting area 100% open.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
The HP rp3000 should not be oriented in a towered position.
A max power saving feature is available in F-10 Setup. When enabled the system will consume <1W of power when OFF (S5)
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight.
Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency Range
Rated Input Current
Heat Dissipation
Power Supply Fan
ENERGY STAR Compliant
FEMP Standby Power Compliant
(<2W in S5 – Power
Off)*
Power Consumption in ES Mode –
Suspend to RAM (S3)
(Instantly Available PC)
Processor/Cache Memory Power -
Down (S3)
Optical Drive Spins Down When Not
In Use
* Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake on LAN"
feature disabled in F10 Setup (default is "enabled").
Operating: 20% to 85% (non-condensing at ambient)
Non-operating: 5% to 90% (non-condensing at ambient)
DA - 13113 North America — Version 13 — June 21, 2013
HP rp3000 Point of Sale (POS) System
Operating: 50° to 104 F (10° to 40° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
150-watt -power supply - Active PFC
90 to 264 VAC
100 to 240VAC
50/60 Hz
47 – 63 Hz
3 A @ 90 VAC
Typical 150 btu/hr
Maximum 785 btu/hr
50 mm two ball bearing fan
No
Yes
< 3 W
< 1.84 W