Programming
Step 1S
Step 2S
fIlTerInG
TYPe
SeT
Step 3S
relaY 1 "GallOnS"
TrIGGer
SeT
Step 4S
relaY 1 SeTPOInT
500
SeT
Gal
Step 5S
relaY 1 duraTIOn
10:00
MIn
SeT
Step 6S
relaY 2 "TIMe"
TrIGGer
SeT
Step 7S
relaY 2 SeTPOInT
0
SeT
MIn
Step 8S
relaY 2 duraTIOn
10:00
MIn
SeT
9
– Must be Rev P100.13 or Greater
FILTER sETup
= Up Arrow
STeP 1S – Press NEXT and simultaneously for 3 seconds. If screen in Step 2S does
not appear in 5 seconds the lock on the valve is activated.
STeP 2S – Select between softening or filtering. A flashing "SOFTENING" or
"FILTERING" will appear. Choose FILTERING using or button. factory setting is
filtering. Press NEXT to step through filter programming to relay programming displayed
on Step 3S. Press REGEN to exit Filter System Setup.
STeP 3S – Set relay 1 Trigger. Gallons chosen to activate relay. If Off or Time was se-
lected in previous steps, this screen does not appear use
trigger to gallons. Press NEXT to got to step 4S. Meter does not read during regeneration.
STEP 4S – Use up and down arrows to select number of gallons per relay activation of
regen gallon setting. Range = 0.1-20,000 gallons. Press NEXT to go to Step 5S.
STeP 5S – Use up and down arrows to set duration of relay activation in minutes.
Range = 1 second - 500 minutes. Recommended duration is 10:00 minutes. Press NEXT
to go to Step 6S. Press REGEN to return to previous step.
STeP 6S – Set relay 2 Trigger. Use
Press NEXT to got to step 7S. Meter does not read during regeneration.
STEP 7S – Use up and down arrows to select number of minutes after start of regeneration
that relay closes and initiates air recharge cycle. Range = 20 - 500 minutes. Press NEXT
to go to Step 8S.
STeP 8S – Use up and down arrows to set duration of relay activation in minutes.
Range = 1 second - 500 minutes. Recommended duration is 10:00 minutes.
Press REGEN to return to previous step.
= Down Arrow
or down arrows to set relay 2 trigger to time.
or down arrows to set relay