NO HARD BYPASS
ENABLED
SET
AUX MAV OFF
STEP 8CS
TRIGGER
SET
RECLAIM START
STEP9CS
30:00
MIN
SET
RECLAIM DURATION
STEP 10CS
6:00
MIN
SET
AUX MAV SEP SOURCE
STEP 11CS
TRIGGER
SET
AUXILIARY INPUT
STEP 12CS
ON 0
REG
SET
STEP 13CS
bacKWaSH
cYcle1
SeT
STEP 14CS
rInSe
cYcle 2
SeT
11
STEP 7CS – No Hard Water Bypass Enabled - Use  or  buttons to select NO HARD
STEP 7CS
WATeR BYPASS eNABLe. Selection requires that a connection to a Motorized Alternator
Valve (MAV) is made to the two pin-connector labeled ALTeRNATOR MAV DRIVe located
on the printed circuit board. The MAV will be driven closed before the first regeneration
cycle that is not FILL or SOFTeNINg or FILTeRINg, and be driven open after the last
regeneration cycle that is not FILL. Press NeXT to go to Step 8C.
STEP 8CS – Use the  or  buttons to select one of the following:
• Reclaim
• Seperate Source
• Off
Press NEXT to go to Step 9CS. Press REGEN to return to previous step.
STEP 9CS – Only displays if reclamation is enabled in Step 8CS. Use the  or  buttons to
select the number of minutes after the start of regeneration before the MAV will divert waste
water from the plumbing drain receptacle to a specified drain. Start of regeneration is defined
as first mode that is NOT draw or filtering. Press NeXT to go to Step 10CS. Press RegeN to
return to previous step.
STEP 10CS – Only displays if reclamation is enabled in Step 8CS. Use the  or  buttons
to select the number of minutes to divert the brine waste water. After the minutes count down
to zero, the waste water will once again be diverted to the plumbing drain receptacle. Press
NEXT to go to Step 11CS. Press REGEN to return to previous step.
STEP 11CS – Seperate source selection requires connection of motorized alternator valve
(MAV) to Auxiliary Drive two-pin connection on board.
Auxiliary MAV Drive set to operate with a Seperate Source trigger. Auxiliary MAV transitions
to Bypass before the start of regen cycle #1, AFTeR Alternator MAV motor transition. Auxiliary
MAV transitions back to Service at the completion of the last programmed regen cycle, once the
Valve Motor deactivates and BeFORe Alternator MAV transition (if scheduled). Auxiliary MAV
will NOT automatically return to Service while manually stepping valve through regen, MAV will
remain in Bypass until regen cycle end. Press NeXT to go to Step 12CS. Press RegeN to
return to previous step.
STEP 12CS – This display will be available to select the use of an outside signal to control the
initiation of a regeneration. Selection only matters if a connection is made to the two pin connec-
tor labeled DP SWITCH located on the printed circuit board. Following is an explanation of the
options:
• ON 0 RegeN – If the dP switch is closed for an accumulative time of 2 minutes, a regenera-
tion will occur immediately.
• DeLAY RegeN – If the dP switch is closed for an accumulative time of 2 minutes, a regenera-
tion will occur at the schedule regeneration time.
• HOLD RegeN – If the dP switch is closed a regeneration will be prevented from occurring.
Press NEXT to go to Step 13CS. Press REGEN to return to previous step.
STeP 13cS – Press the  or  buttons until selection of first cycle appears in left upper cor-
ner, in this example BACKWASH is selected. Press NEXT to go to Step 14CS. Press REGEN
to return to previous step.
STeP 14cS – Press the  or  buttons until selection of third cycle appears in left upper
corner, in this example RINSE is selected. Press NEXT to go to Step 15CS. Press REGEN to
return to previous step.