Download Print this page
Olympus IX81-ZDC2 Instructions Manual

Olympus IX81-ZDC2 Instructions Manual

Focus drift compensating microscope

Advertisement

INSTRUCTIONS
IX81-ZDC2
FOCUS DRIFT COMPENSATING
MICROSCOPE
This instruction manual is for the Olympus Focus Drift Compensating Microscope Model IX81-ZDC2.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of
this microscope, we recommend that you study this manual thoroughly before operating the
microscope.
Retain this instruction manual in an easily accessible place near the work desk for future reference.
A X 7 9 0 6

Advertisement

loading

Summary of Contents for Olympus IX81-ZDC2

  • Page 1 FOCUS DRIFT COMPENSATING MICROSCOPE This instruction manual is for the Olympus Focus Drift Compensating Microscope Model IX81-ZDC2. To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of this microscope, we recommend that you study this manual thoroughly before operating the microscope.
  • Page 2 Refer to your local Olympus distributor in EU for return and/or collection systems available in your country. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 3: Table Of Contents

    IX81-ZDC2 CONTENTS IMPORTANT — Be sure to read this section for safe use of the equipment. — MODULE NOMENCLATURE NOMENCLATURE OPERATION SPECIFICATIONS TROUBLESHOOTING GUIDE...
  • Page 4: Safety Precautions

    [Semiconductor laser, wavelength 785 nm, output (max.) 85 mW, equivalent to Class 3B] 3. Always use the power cord provided by Olympus. If the proper power cord is not used, product safety performance cannot be warranted.
  • Page 5: Maintenance And Storage

    Warning label position (AF sensor unit) Left side panel When a warning label becomes dirty or is peeled off, contact Olympus for replacement. Getting Ready 1. The microscope is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe impact.
  • Page 6 Notes on ZDC (Focus Drift Compensation) When using an objective with correction collar, always adjust the collection collar before using the focus CAUTION drift compensation function. Otherwise, the focus drift compensation will not be available. Be sure to use an anti-vibration bench to enable the focus drift compensation to function properly. 1.
  • Page 7 IX81-ZDC2 3. Applicable objectives: CAUTION · If objective has an aperture, set it wide open. · The AF focusing speed is approximately 1 to 5sec. in the focusing range, but slows down depending on the AF search range setting. · The focus drift compensation is not available with the phase contrast objectives because these incorporate a phase plate.
  • Page 8 When this slider is used, the fluorescence mirror unit used in the DIC observation should be the U-MDICT. · If the I2-ZDC2PCB control board for exclusive use with IX81-ZDC2 is installed on the IX2-UCB control box, uninstall other focus control boards.
  • Page 9: Module Nomenclature

    IX81-ZDC2 MODULE NOMENCLATURE } The IX81-ZDC2 can be combined with the same modules as the IX81 microscope systems, but certain modules are subject to restrictions with regard to the combination with the stages, thermal incubation boxes (IBMU/IBML) and interme- diate attachments.
  • Page 10: Nomenclature

    Wavelength : 785 [nm] The assembly and adjustments are to be done by Olympus. Beam divergence : @Objectives attached Also when the system is going to be transported and reinstalled, consult Olympus. 0 to 1.49 [NA] * Depend on objective lens 2Objectives removed Warning label -0.14 to 0.03 [deg]...
  • Page 11: Operation

    IX81-ZDC2 OPERATION 3-1 Operating Precautions The Class 1 laser beam that is output from the objective is not hazardous (but direct staring for an extended period is still inhibited), and the laser beam intensity will not increase even in the case of malfunction. However, to prevent an incident, make sure not to tilt the glass bottom dish so that the reflected laser beam will not be scattered around.
  • Page 12 (Fig. 2) } If you use an oil-immersion objective, use immersion oil as described below. Always use immersion oil supplied by Olympus. CAUTION } If the objective in use can accommodate the oil-proof cap, be sure to mount the cap.
  • Page 13 IX81-ZDC2 Placing the Specimen (Fig. 3) Put the specimen in the glass-bottom dish (with cover glass thickness of 0.16 to 0.18 mm) and place the dish on the center of the stage. } If the dish is prone to slide on the stage, attach the stage clips (IX-SCL) 1 or use the provided weight.
  • Page 14: Specifications

    ±0.1 µm (with less than 5°C temperature change) Dimensions & weight IX81-ZDC2 system : 303 (W) x 313 (H) x 434 (D) mm., 19.2 kg (42.2 lb) AF sensor unit : 76 (W) x 76 (H) x 201 (D) mm., 0.9 kg (2 lb)
  • Page 15: Troubleshooting Guide

    Under certain conditions, performance of the microscope may be adversely affected by factors other than defects. If problems occur, please review the following list and take remedial action as needed. If you cannot solve the problem after checking the entire list, please contact Olympus for assistance. Problem...
  • Page 16 Printed in Japan on May 19, 2010 M 003-01...