6.15.7 Charge Mode Select
Press the MENU key to access the menu data screens. Press the Down arrow key
to access the Charge Mode Select screen.
Press the F1 key to display the following adjustment screen:
Note: Please consult the factory when using this option. DAMAGE to the systems
battery will occur if this is used improperly.
6.15.8 Reset to Default Settings
Press the MENU key to access the menu data screens. Press the Down arrow key
to access the original factory default settings adjustment screen:
Press the F1 key to display the following active adjustment screen:
When the ENTER key is pressed the following factory defaults are reset:
Press the MENU key to abandon the operation and return to the menu data
screen.
T O S H I B A
CHARGE MODE SELECT
EQUAL CHARGE>OFF ON
>F1:DATA SET MODE
>∆/∇:PRV/NEXT SCREEN
CHARGE MODE SELECT
EQUAL CHARGE>OFF ON
>∆/∇:CHANGE DATA
>ENTER:ACCEPT CHANGE
MENU DATA RESET
DATA INITIALIZATION
>F1: TO ACCESS RESET
>∆/∇:PRV/NEXT SCREEN
MENU DATA RESET
DATA INITIALIZATION
> MENU: NO DATA RESET
>ENTER: ACCEPT CHANGE
1) Reset the voltage-reference setting to +0.
2) Reset the buzzer volume to loud.
3) Reset the serial station address to 31h.
4) Reset the idle mode to 3 minutes.
55