Supero SUPERSERVER 6016TT-TF User Manual page 55

1u twin (two serverboards in a 1u chassis) rackmount server
Hide thumbs Also See for SUPERO SUPERSERVER 6016TT-TF:
Table of Contents

Advertisement

LAN1/LAN2 Enable/Disable
Change the setting of jumper JPL1 to
enable or disable the LAN1 and LAN2
ports. See the table on the right for
jumper settings. The default setting
is enabled.
Power Setting Select
JPEN1 allows you to confi gure power
settings for hot-swap support on the
Hot-Swap version of Chassis 827. To
enable hot-swap support for this model
of chassis, connect a cable to Pins 2~3
of JPEN1. To use the regular power
setting for other chassis, close Pins
1~2 on JPEN1 with a cap. See the
table on the right for jumper settings.
Red LED Overwrite Enable/Disable
When jumper J_UID_OW is open (the
default setting), the red LED for Over-
heat/Fan Fail/PWR Fail/UID LED (see
pin 8 of JF1) will overwrite the signal
from the blue UID LED (see pin 7 of
JF1). That is, when the red LED is on,
the blue LED will be turned off (when
the red LED is off, the blue LED can be
on or off). When this jumper is closed,
the red and blue LEDs work indepen-
dently of each other. See the table on
the right for jumper settings.
BMC Enable/Disable
Use jumper JPBMC1 to enable or
disable the Winbond WPCM450 BMC
(Baseboard Management Controller),
which supports IPMI 2.0. See the table
on the right for jumper settings.
Chapter 5: Advanced Serverboard Setup
LAN1/2 Enable/Disable
Jumper Settings
Jumper Setting
Pins 1-2
Pins 2-3
Power Setting Select
Jumper Settings
Jumper
Defi nition
Pins 1-2
Pins 2-3
Red LED Overwrite Enable/Disable
Jumper Settings
Jumper
Defi nition
Open
Red OH/Fan Fail/PWR Fail LED
(pin 8 of JF1) takes precedence
over the Blue UID_LED (pin 7
of JF1).
Red LED: On, Blue LED: Off,
Red LED: Off, Blue LED: On or Off
Closed
Red nad Blue LEDs function
independently.
Red LED: On, Blue LED: On,Off
Red LED: Off, Blue LED: On, Off
BMC Enable/Disable
Jumper Settings
Both Jumpers
Pins 1-2
Pins 2-3
5-21
Defi nition
Enabled
Disabled
Onboard PWR setting
Hot Swap support
Defi nition
Enabled
Disabled