( ( ( ( 3) ) ) ) 2PULSE
Accumulation of charges is started and ended through the trigger pulse input to the DC IN/SYNC terminal or
trigger signal input (LVDS) to the DIGITAL terminal, the vertical sync signal is reset and field images are
output.
Trigger pulse level
(DC IN/SYNC terminal)
Trigger pulse fetch timing
・When the trigger pulse fetch timing is set to pulse width
Trigger pulse width
Trigger pulse interval
・When the trigger pulse fetch timing is set to rising edge or falling edge
Trigger pulse width
Trigger pulse interval
: (Low Level):Less than 0.5V , (High Level):3.4V to 5V
: Rising edge / Falling edge / Pulse width selectable
: More than 20ms(FLD/FRM setting:FLD)
More than 40ms(FLD/FRM setting:FRM)
: More than 20ms(FLD/FRM setting:FLD)
More than 40ms(FLD/FRM setting:FRM)
: More than 2μs
: More than 20ms(FLD/FRM setting:FLD)
More than 40ms(FLD/FRM setting:FRM)
- 45 -