13 [ EMRG ]
Function: Emergency channel On/Off
Available Values: on/oFF
Default Setting: on
This controls the operation of the Emergency [ 121.5 ]
key. When set to "oFF," this key will not function.
You can still use the frequency 121.5 MHz either by
entering it on the keypad in the VFO mode, or by
recalling it on a previously-stored memory channel.
44
(
)
M
"S
"
M
ENU
ET
14 [ TEMP ]
Function: Correcting the Thermometer setting
Available Values: –12.7 ~ +12.7 °C
Default Setting: 0 °C
This allows you to calibrate the internal thermom-
eter with a known-to be-accurate source.
15 [ BARO ]
Function: Correcting the atomspheric pressure
Available Values: –127 ~ +127 hpa
Default Setting: 0 hpa
This allows you to caliblate the Barometer in the
optional SU-1 Sensor Unit with a known-to be-ac-
curate source.