IDS 805 Installer Manual
Hide thumbs Also See for 805:

Advertisement

1
IDS 805 Installer Manual 700-266-02H Issued September 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 805 and is the answer not in the manual?

Questions and answers

nico
May 28, 2025

remote on ids 8 zone stopped working

User image 6836d607a74ad

Summary of Contents for IDS 805

  • Page 1 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 2 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 3: Table Of Contents

    Event Log ......................12 Dialler Progress Mode ..................12 Download Code ....................13 Programming Instructions ..................13 12.1 Introduction ........................13 12.2 Location Values ......................13 12.3 Programming the Panel ....................14 12.4 Program Location Summary ..................15 Index ..........................44 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 4 Table 5: Programmable Zone Types..................16 Table 6: Output Options......................22 Table 7: Output Options Default Values.................23 Table 8: Standard Contact ID Reporting Codes..............27 Table 9: Alarm Reporting Codes.....................28 Table 10: Trouble Conditions....................39 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 5 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 6 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 7: Introduction To The Ids 805

    Introduction to the IDS 805 The IDS 805 is a versatile, state of the art, microprocessor based, eight-zone Alarm Panel. Most features are optional and may be programmed either directly through the keypad or via the telephone system, using the IDS download software and appropriate modem. There are eight programmable burglary zones, appropriate siren, auxiliary power outputs and 5 outputs which may be programmed to perform various trigger/switching functions.
  • Page 8: Installation And Wiring

    Installation and Wiring Please refer to Figure 1: Connection Diagram and familiarise yourself with the following sections. Figure 1: Connection Diagram - without tamper per zone IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 9: End-Of-Line Resistors/Tamper Per Zone

     should be connected as per Figure 2 below. The 4K7 and 12K resistors are not included with the panel but may be obtained from your local distributor of IDS products. Figure 2: Tamper per Zone Connection The operation of the tamper is as follows: If the panel is not armed and a tamper condition occurs, the siren will not sound but a tamper ...
  • Page 10: Connecting The Telephone Communicator

    If using a remote control, program the zone as either a Panic zone or an Arm/Disarm zone, as  required. The panel will arm instantly (no entry/exit delay) when arming by means of a key-switch or remote  control unit. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 11: Additional Technical Data

    If the reset switch has been disabled, it is not possible to default the panel using the reset switch. The panel may only be defaulted if a valid installer code is used and a value of [0] is entered into location 0. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 12: Event Log

    The IDS 805 does not contain an onboard battery to maintain the clock time in the event of a total power failure (AC mains failure and discharged battery) therefore in the event of a total power failure it will not be possible to calculate the absolute time at which an event took place.
  • Page 13: Download Code

    Zone 1, Zone 3, and Zone 4. The value would be as shown in the table below. Zone 1 Zone 3 Zone 4 Total IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 14: Programming The Panel

    Repeat steps 5-8 until all necessary locations have been programmed. To exit from the programming mode press the [#] key. The READY indicator will stop flashing to indicate that the program mode has been exited. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 15: Program Location Summary

    Table 5 overleaf provides a description of the different zone types that may be programmed into these locations i.e. a value of 3 programmed into location 5 would cause zone 5 to be an audible priority zone. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 16: Table 5: Programmable Zone Types

    PUSH TO ARM If the value in location 18 is 15, once the exit delay has commenced, a violation of the Push to Arm zone will immediately arm the panel. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 17 If a subsequent violation of a secondary Entry/Exit zone occurs, the panel will continue to count down the primary delay. If a valid user code is not entered during this period, an alarm condition will occur. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 18 If a zone which has been automatically bypassed clears while the panel is armed, the zone will become active i.e. the window is pushed closed. Opening the window again will cause an alarm condition to be registered. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 19 If a zone is programmed as a Silent Instant zone, an alarm condition as a result of a violation of this zone would be silent regardless of the value programmed into this location. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 20 This is the period of time allowed for exiting before the panel arms. The exit delay begins after entry of a valid user code. During this period, it is possible to violate Entry/Exit and Follower zones without causing an alarm condition. Select the appropriate exit delay period from the table above. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 21 Select the appropriate value for the primary entry delay from the table above. LOCATION 21 Hardware Reset Switch Enable/Disable WARNING: Make certain that the new installer code has been correctly entered before disabling the reset switch. Value Action Disable 15 Default Enable IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 22: Table 6: Output Options

    The strobe and fire-detect outputs may only be programmed with [0] to [5] i.e. a pulsed output.  The second phone number dialled output can only be programmed with values [1] - [5] ([0] will  disable the output). IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 23: Table 7: Output Options Default Values

    2 low. Therefore, if a value of [12] is programmed into location 29 output 2 will be set low on an open condition. If an output is programmed as a strobe output, the output will follow the sequence illustrated below. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 24: Figure 5: Strobe Output Sequence

     The primary and secondary numbers may be joined to provide for a single number up to 32  digits. The numbers can be dialled using either tone or pulse dialling.  IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 25 If dual reporting is selected, program the following locations:  Locations 43-46 Primary Account Number Location 47 Primary Communicator Format Locations 48-63 Primary Phone Number Locations 64-79 Secondary phone Number Locations 152-155 Secondary Account Code Location 156 Secondary Communicator Format IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 26 NOTE ON DUAL REPORTING If dual reporting is enabled both base stations will receive the codes programmed into locations 80 - 133. Codes that are disabled are disabled to both communicator formats. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 27: Table 8: Standard Contact Id Reporting Codes

    BURGLARY an option may be chosen from Table 9 overleaf. The first digit of the reporting code relevant to that zone must be changed to the value as indicated in the table. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 28: Table 9: Alarm Reporting Codes

    These locations contain the primary telephone number, which may be up to sixteen digits long. A four- second delay can be programmed at any point by entering a value of [15] in the respective location. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 29 Hexadecimal Value LOCATIONS 80-81 Duress Reporting Code This code will be reported if the panel is disarming using the duress code (User 15 is the duress code – see the User Manual). IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 30 (See User Manual). EXAMPLE: If a close code of C (12) is programmed and the master user code is used to arm the system the 2 digit IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 31 This code will be reported if the medical button [M] on the keypad is pressed until the keypad beeps repeatedly (approximately 1 second). LOCATION 117 Bypassed Zone Reporting Code A zone bypass code will be reported if the panel is armed with a bypassed zone. The zone number will IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 32 AC power is present. LOCATIONS 130-131 Low Battery Restoral Reporting Code This code will be sent once the battery voltage has been restored. The battery voltage has to rise to IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 33 4-digit code into these 4 locations. Although not possible from the keypad, it is possible using the IDS PC download software to enter an installers ID code containing the hexadecimal digits A-F. If these digits are used as part of the installers ID, it will prevent access to programming mode from the keypad.
  • Page 34 Should the display be disabled no trouble condition will be shown i.e. the power LED will not flash and no trouble condition shown when entering trouble-viewing mode. However, reporting codes, if programmed, will be reported to the base station. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 35 1 minute. The panel will pick up the call on the first ring thereby preventing the fax/ answering machine from answering the call before the Alarm Panel. A number lower than 15 programmed into this location disables the fax defeat mode. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 36 This account code is used if the panel is communicating to two base stations and will be transmitted to the secondary phone number. See Locations 43 - 46 for information regarding the programming of these locations. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 37 30-60 seconds. LOCATION 168 TLM Restore programmable Output (Default = 0) This output will be triggered once telephone line monitoring has been restored to 9V for longer than 30-60 seconds. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 38 This location sets the time at which the panel will automatically arm every day (if enabled). The auto arm feature is disabled by entering an invalid time greater than 2400 e.g. 9999. IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 39: Table 10: Trouble Conditions

    Telephone line is cut or not present The siren wire has been cut or the fuse has blown Keypad has experienced a tamper Installers code must be entered to clear an alarm condition IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 40 Disabled Aux. Chime Prog. O/P Disabled Comms Fail Prog. O/P Disabled Phone Number 2 Prog. O/P Disabled D/L Complete Disabled Primary Communication Options Dialling Options Tone Primary Account Code Digit 1 Disabled IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 41 Keypad Panic Reporting Code Digit 2 Disabled Keypad Tamper Reporting Code Digit 1 Disabled Keypad Tamper Reporting Code Digit 2 Disabled Zone 1 Alarm Reporting Code Digit 1 Disabled Zone 1 Alarm Reporting Code Digit 2 Disabled IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 42 Low Battery Restore Rep. Code Digit 1 Disabled Low Battery Restore Rep. Code Digit 2 Disabled Box Tamper Rep. Code Digit 1 Disabled Box Tamper Rep. Code Digit 2 Disabled Reserved Reserved IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 43 TLM Fail Prog. O/P Disabled TLM Restoral Prog. O/P Disabled Siren Tamper Prog. O/P Disabled Box Tamper Prog. O/P Disabled System Time Disabled Auto Test Time 1a.m. 0100 Automatic Arm Time Disabled 9999 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 44: Index

    Download Code............................13 Download Complete Reporting Code......................32 DTMF................................26 Dual Reporting.......................7, 24, 25, 26, 27, 28 Duress..........................23, 27, 29, 37, 47 End-of-Line Resistors........................7, 9, 16, 18 Engineer Reset..........................18, 19, 35 Entry Delay............................16, 17, 21 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 45 Power Failure..........................7, 12, 21, 39 Primary Communicator Format..................see "Communicator" Primary Entry Delay........................see "Entry" Programmable Outputs....................10, 16, 22, 23, 37, 38 Programming Mode........................14, 33, 38 Push to Arm Zone.........................see "Zone" Quick Arm............................18, 19, 31 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 46 Instant..........................16, 19, 21, 34 Panic..........................7, 9, 10, 11, 27 Primary Entry/Exit..........................16, 21 Push to Arm............................16 Secondary Entry/Exit........................16, 17 Silent Instant..........................16, 19 Silent Priority...........................16, 23, 37 Stay...............................19, 47 Trip Count.............................33 Trip Count Time Delay..........................34 IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 47 Hold down [3] for 1 second + [ZONE NUMBER] + [*] Program buzz zone Hold down [4] for 1 second + [ZONE NUMBER] + [*] View Trouble Status Hold down [7] for 1 second Duress [#] + [DURESS CODE] IDS 805 Installer Manual 700-266-02H Issued September 2009...
  • Page 48 IDS 805 Installer Manual 700-266-02H Issued September 2009...

This manual is also suitable for:

Ids805

Table of Contents

Save PDF