5 Winter storage procedure

VD01006

1 Fuel system

Drain the water from the water separator/
fuel filter and the fuel tank. Ensure that the
tank is completely filled with fuel.
48
VD00136
Running with protective fuel mixture
Connect the fuel supply pipe to a can filled
with a mixture of one (1) part of engine oil*
to nine (9) parts of clean fuel**. Use this
mixture to run the engine at no load for
approx. 10 minutes.
Stop the engine.
* Engine oil with protective properties.
E.g. Shell Super Diesel T 10W40
** Preferably water-free fuel.
Collect some fuel from the return pipe,
while engine is running.
Never run the engine under load with this
mixture of fuel and oil.