4 Maintenance
i
,
.
: StM8061
Mpeller
art
Code
VD00127
44 Impeller inspection
• Inspect the impeller for damage.
• Replace the impeller if necessary.
VD00004
45 Re-install the impeller
• The impeller should be lubricated with
glycerin or a non-petroleum based lubri-
cant such as a silicone spray before fit-
ting it into the impeller housing.
• Fit the impeller to the pump shaft. (if an
existing impeller is re-used, install it in
the same position as removed).
Raw water pump inspection
Every 1000 operating hours.
o-r
,
.
:
ing
art
Code
STM7686
VD00582
46 Replacing the pump cover
• Replace the cover with a new O-ring.
• Check the water filter and open the sea
cock.
STM7696