Instructions for the installer

7. POSITIONING IN THE COUNTER TOP

The following operation requires building and/or carpentry work and must be
carried out by a competent tradesman.
Installation can be carried out on various materials such as masonry, metal,
solid wood or plastic laminated wood as long as they are heat resistant (T
90°C).
If installed on top of an oven, the latter must be equipped with a cooling fan.
7.1
Section cut from the work surface
Create an opening with the dimensions shown in the figure in the top surface of
the counter, keeping a minimum distance of 50 mm from the rear edge. This
appliance can be mounted against walls higher than the work surface on
condition that a distance X be kept between the appliance and the wall as
shown in the figure so as to avoid damage from overheating. Any wall units must
be at a minimum distance of at least 750 mm above the appliance. This distance
can be reduced to 650 mm if a ventilation hood is installed.
In case of installation on an empty kitchen unit with doors, a separation panel
must be placed under the hob. Keep a minimum distance of 10 mm between the
bottom of the hob and the surface of the panel, which must be easily extractable
to allow sufficient access for any technical assistance.