6. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open
position (see letter "A" in Figure 5).
7. Holding the DIMM by the edges, remove it from its anti-static package.
8. Position the DIMM above the socket. Align the notch on the bottom edge of the DIMM with
the key in the DIMM socket (see letter "B" in Figure 5).
9. Insert the bottom edge of the DIMM into the socket (see letter "C" in Figure 5).
10. When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips
snap into place. Make sure the clips are firmly in place (see letter "D" in Figure 5).
11. Replace the server's cover and reconnect the AC power cord.