26017XX1

Technical Information

Recommended water pressure
Minimum water pressure
Max. water pressure
Recommended hot water temp.
Max. hot water temp
Max. flow rate:
showerhead
handshower
neck spray
bodysprays
Thermostatic temperature control
The high temperature limit stop on the thermostatic mx-
ing valve may be reset to comply with local plumbing
codes.
Protection against back siphonage provided by check
valves. The check valves should be removed and
inspected yearly.
This panel may be used with an instantaneous water
heater if the heater is at least 24 kW and the output is
at least 3 gpm @ 30 psi pressure. However, only one
panel function may be used at a time.
*Please know and follow all applicable local plumbing codes when setting
the temperature on the water heater. In Massachusetts, the water heater
may be set no higher than 112�F.

Installation Considerations

For best results, Hansgrohe recommends that this unit
be installed by a licensed, professional plumber.
Please read over these instructions thoroughly before
beginning installation. Make sure that you have all
tools and supplies needed to complete the installation.
A minimum of two people is required to install
this panel. Do not attempt to install this panel
alone as injury or damage to the panel may result.
2
14.7 - 72.5 psi
29 psi
147 psi
120� - 140� F*
165�F*
2.5 gpm
2.5 gpm
2.5 gpm
0.72 gpm each
showerhead
neck spray
handshower
bodysprays
foot rest