Cleaning the hand and overhead
showers
The handshower and overhead shower use the Rubit
self-cleaning system.
If scale deposits are noticed in the spray channels,
turn the water on lightly and rub over the channels
with a finger or a sponge to dislodge them.
Troubleshooting
Problem
Outputs both hot and cold water,
but no mix
Insufficient water
Erratic water temperature
Function drips, won't shut off
completely
Hot water bleeds over into cold
water supply in house or vice-
versa

Maintenance Note:

The check valves located in the hot and cold elbows
should be removed and inspected yearly.
If the flow of water decreases over time, clean the
filters.
8
TM
Possible cause
Not a product defect Supply
lines connected to the incorrect
elbows
Filters inside supply elbows
clogged
Thermostatic mixer cartridge faulty
Volume control cartridge faulty
Faulty check valve
Solution
Reconnect supply lines to correct
elbows
Remove and clean filters
Replace thermostat cartridge
Replace volume control cartridge
Remove and clean check valve,
replace if necessary
filter
check valve