Direct Input Master Controls - Midas SIENA Operator's Manual

Table of Contents

Advertisement

Master Section:
Master Section:
master meters
left
right
21
21
18
18
15
15
12
12
9
9
6
6
3
3
0
0
3
3
6
6
9
9
12
12
15
15
18
18
21
21
send to feed signals to an external reverberation unit. Connecting the reverb return to the direct input allows you to
24
24
add reverb back to each of your artist's monitor sends, without needing to use an additional pair of input channels
solo meters
for this purpose.
left
right
21
21
18
18
15
15
The direct input is a stereo line level feed available on the rear panel of the master section. It features its own input
12
12
level control, solo and mute facilities as follows:
9
9
6
6
3
3
0
0
3
3
6
6
Direct Input Level
9
9
12
12
level provides continuous adjustment of
15
15
18
18
input level from off (-inf) to +20dB. Use
21
21
24
24
this control to set the optimum input
1
50
500
direct input
level for the stereo direct input.
0
MUTE
50
5k
frequency
SOLO
20
0
direct to
0
masters
10
generator
6
talk mic
Direct to Masters Level
3
1
2
control sets the level of the direct input
NEUTRIK
applied to the stereo master bus when
15
60
talk gain
the
auto
mute
talk
talk
depressed. Level may be adjusted from
on
ext
masters
input
off (-inf) to +6dB.
1-2
1
3-4
Note: the
5-6
2
located above the mix bus output master
7-8
faders adjust the amount of direct input
9-10
3
signal added to the each of the 16 mix
1
1-1
2
busses. For more details on these
4
1
3-1
4
controls, please refer to Page 16.
input / output
1
5-16
5
masters
monitor
add
clear
phones
Tone Generator (Oscillator)
0
SOLO
SOLO
input
output
10
PFL
PFL
MUTE
The Siena provides an internal tone generator which may be routed to any of the console's 16 mix bus and stereo
local
auto mute
master outputs.
5
5
mono sum
When enabled, the output of the tone generator is added to the talk bus where it may be combined with the
MUTE
MUTE
MUTE
console's talk mic and external talk inputs. The combined signals are then routed to any of the bus masters using
left
right
mono
the 'talk to mix' and 'talk to masters' switches located in the Talkback section.
SOLO
SOLO
MUTE
stereo
masters
Note: to route only the tone generator to a mix bus output or stereo master, without talkback, make sure that both
10
10
the
talk on
5
5
0
0
5
5
10
10
15
15
20
20
30
30
40
40
Generator On
generator.
S0011
The direct input
This level
Direct
to
Masters
switch
direct 1
to
direct 16
controls
and
talk ext
switches are disabled.
Enables the tone
Stereo Master & Monitoring Controls
Stereo Master & Monitoring Controls

Direct Input Master Controls

In addition to the console's input channels, Siena features a
single stereo direct input (line level) which may be added to
any of the 16 mix bus outputs or stereo master.
A common application is to use the direct input as a stereo
effects return. For example, you may be using an auxiliary
1
50
500
direct input
0
MUTE
50
frequency
SOLO
20
0
direct to
0
masters
generator
6
is
1
50
500
direct input
direct input
0
MUTE
50
5k
frequency
SOLO
20
0
direct to
direct to
0
masters
10
generator
6
Operators Manual - Page 20
Mute
The
MUTE
switch mutes the direct
input cutting off all feeds except to the
PFL bus. The mute status is indicated by
the corresponding mute LED.
5k
Solo
The
SOLO
switch routes the direct
input signal onto the mono PFL and
10
stereo AFL busses. The solo status is
indicated by the solo LED.
Direct to Masters
When depressed,
this switch routes the stereo direct input
to the master stereo bus, via the Direct
to Masters level control.
Frequency The output frequency of the
generator is continuously variable from
50Hz to 5kHz allowing the user to test,
for example, three or four bands of a
crossover system.
Generator Level
The level of the
generator
output
is
variable from off (-inf) to +10dB.
continuously

Advertisement

Table of Contents
loading

Table of Contents