Supply voltage selector switch:
230VAC, and should be set to the mains power supply available in the country in which the unit is
to be used.
Caution!
The supply voltage selector switch must be set BEFORE plugging the unit into the mains.
UNDER NO CIRCUMSTANCES should the switch be changed whilst the unit is plugged in.
WARNING
DO NOT EXPOSE
THIS APPLIANCE TO
RAIN OR MOiSTURE
SUPPLY
VOLTAGE
Automute link/Automute input: Automute link socket can be used
to extend the Automute connection to other XL42s in the daisy chain.
Automute input should be wired according to diagram below.
1 2 3 4 5
6 7 8 9
5 4 3 2 1
9 8 7 6
The supply voltage is switchable between 115VAC and
Remote Control Automute Assigns: The 9-pin plug for the
Automute system allows up to 8 Automute channels. The input
channels of the XL42 can be set to mute on one of these 8 Automute
channels by switching on the corresponding channel number on the
DIP switch for the XL42's input channels.
AUTOMUTE INPUT
REMOTE CONTROL
AUTOMUTE ASSIGNS
RIGHT
AUTOMUTE LINK
Pin 1 Automute 1
Pin 2 Automute 2
Pin 3 Automute 3
Pin 4 Automute 4
Pin 5 Automute 5
Pin 6 Automute 6
Pin 7 Automute 7
Pin 8 Automute 8
Pin 9 Common
Left and right insertion points: Insert points can be used to add
additional processing into the signal path, for example, Dynamics
Processors, Graphic EQ, Effects, etc.
Input impedance:
Maximum input level:
The insert send and return are on independent balanced Bantam Jacks.
The insert point can be configured internally using jumpers to be pre- or
post- EQ. The factory default setting is Pre-EQ.
XL42 Operators Manual - Page 11
Rear Panel
Rear Panel
NRTL/C
INSERTION POINTS
RIGHT
LEFT
RETURN
SEND
20kOhm Balanced
+21dBu
1995
LEFT
RETURN
SEND

Hide quick links: