Imager Time-Out

Imager Time-Out powers down the imager after the unit has been idle for the
specified time. To prevent the imager from powering down, set this time-out to
0. Scan the bar code below, then set the time-out by scanning digits (from 0 -
999,999 ms) from the inside back cover, then scanning Save . Default = 60,000
ms.
Note: The default applies to firmware with a base number of 31205480. Refer
to the
Show Software Revision
determining the firmware revision in your unit.

Aimer Delay

The aimer delay allows a delay time for the operator to aim the imager before the
picture is taken. Use these codes to set the time between when the trigger is
pulled and when the picture is taken. During the delay time, the aiming light will
appear, but the LEDs won't turn on until the delay time is over.
200 milliseconds
* Off
(no delay)

User-Specified Aimer Delay

If you want to set your own length for the duration of the delay, scan the bar code
below, then set the time-out by scanning digits (0 - 4,000 ms) from the
Programming Chart
3 - 10
Imager Time-Out
inside the back cover of this manual, then scan Save.
Delay Duration
on page 11-2 for information on
400 milliseconds