Oemgetsetuprss; Oemgetsetupstrt25 - Hand Held Products 4X00 Software Manual

Imageteam 4x00 series software development kit (sdk)
Hide thumbs Also See for 4X00:
Table of Contents

Advertisement

oemGetSetupRSS

This function is used to get the RSS Expanded symbology-specific options.
Result_t
oemGetSetupRSS (
SetupType_t SetupType,
BOOL *pEnabled,
WORD *pMinLength,
WORD *pMaxLength
)
Return Values
RESULT_SUCCESS
RESULT_ERR_PARAMETER
Parameters
SetupType
SETUP_TYPE_CURRENT for current settings, or SETUP_TYPE_DEFAULT for default settings.
pEnabled
Points to a BOOL variable that contains the enabled state of this symbology upon returning from the function. A TRUE
means the symbology is enabled; a FALSE means the symbology is disabled.
pMinLength
Points to a WORD variable that contains the minimum length decoded RSS message the engine should return. RSS
messages smaller than this minimum length are not reported by the engine. The default value is 1.
pMaxLength
Points to a WORD variable that contains the maximum length decoded RSS message the engine should return. RSS
messages larger than this maximum length are reported by the engine. The default value is 80.

oemGetSetupStrt25

This function is used to get the Straight 2 of 5 symbology specific options.
Result_t
oemGetSetupStrt25 (
SetupType_t SetupType,
BOOL *pEnabled,
WORD *pMinLength,
WORD *pMaxLength
)
Return Values
RESULT_SUCCESS
RESULT_ERR_PARAMETER
Parameters
SetupType
SETUP_TYPE_CURRENT for current settings, or SETUP_TYPE_DEFAULT for default settings.
pEnabled
Points to a BOOL variable that contains the enabled state of this symbology upon returning from the function. A TRUE
means the symbology is enabled; a FALSE means the symbology is disabled.
pMinLength
Points to a WORD variable that contains the minimum length decoded Straight 2 of 5 message the engine should return.
Straight 2 of 5 messages smaller than this minimum length are not reported by the engine. The default value is 4.
pMaxLength
Points to a WORD variable that contains the maximum length decoded Straight 2 of 5 message the engine should
return. Straight 2 of 5 messages larger than this maximum length are not reported by the engine. The default value is