Minimum Clearance To Combustible Materials - HAMPTON BAY H300 Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

INSTALLATION
Please read the section below carefully. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the
rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
* Minimum clearance with
side load door in use is 18"
(457mm) to side wall or refer
to dimension (A) if side load
door is not used.
Residential Installation "C" Vent (Single Wall)
Unit (with Heat Shield)
H300
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling
level.
Unit (with Heat Shield)
H300
Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home section).
Unit (with Heat Shield)
H300
8
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
From Unit
A
B
17" (431 mm) 15" (381 mm) 13" (330 mm) 30" (762 mm)
From Unit
A
B
15" (381 mm) 10" (254 mm)
From Unit
A
B
15" (381 mm)
10" (254 mm)
From
From Flue Center-Line
Corner
C
D
15" (381 mm)
From
From Flue Center-Line
Corner
C
D
9" (228 mm)
28" (711 mm)
From
From Flue Center-Line
Corner
C
D
9" (228 mm)
28" (711 mm) 10" (254 mm)
Hampton H300 Cast Freestanding Woodstove
E
F
19" (483 mm)
E
F
10" (254 mm) 15" (381 mm)
E
F
15" (381 mm)