Safety Label; Safety Label For H300 - HAMPTON BAY H300 Owners & Installation Manual

Freestanding woodstove
Table of Contents

Advertisement

SAFETY LABEL

This is a copy of the label that accompanies
each Hampton H300 Freestanding Woodstove.
We have printed a copy of the contents here
for your review.
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS
MEASURE
FROM
RESIDENTIAL INSTALLATION USING
SIDEWALL
BACKWALL B 381 mm / 15 in
CORNER
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - MOBILE HOME
SIDEWALL
BACKWALL B 254 mm / 10 in
CORNER
INSTALLATION USING LISTED DOUBLE WALL
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE
SIDEWALL
BACKWALL B 254 mm / 10 in
CORNER
INSTALLATION USING LISTED DOUBLE WALL
SIDEWALL
BACKWALL H 330 mm / 13 in
MINIMUM ALCOVE CEILING HEIGHT: 1.5 M / 5 FT
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 457 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT
COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE
ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR
GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE
BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH
NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO
THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL.
OPTIONAL COMPONENT: FAN (846-515), ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF
APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM:
SECURITY MODEL S2100, ICC EXCEL 2100.
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT
MODEL DVL, GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL. CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY
MODEL S2100 OR MODEL ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB
TEMP/GUARD, AMERI-TECHS, ICC EXCEL 2100 . USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS.
UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY
4
NOTE: Hampton units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.

SAFETY LABEL FOR H300

LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO
SUITABLE FOR MOBILE HOME INSTALLATION
MODEL: HAMPTON CAST FREESTANDING WOOD STOVE - H300
TESTED TO: UL 1482 / ULC S627
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR
AREA. USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED
UL103 HT FACTORY-BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A
CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE
WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FLUE
HEATER
CENTER-LINE
SINGLE WALL CONNECTOR
A 431 mm / 17 in
D 762 mm / 30 in
E 381 mm / 15 in
C 330 mm / 13 in
F 483 mm / 19 in
A 381 mm / 15 in
D 711 mm / 28 in
E 254 mm / 10 in
C 228 mm / 9 in
F 381 mm / 15 in
A 381 mm / 15 in
D 711 mm / 28 in
E 254 mm / 10 in
C 228 mm / 9 in
F 381 mm / 15 in
CONNECTOR - ALCOVE
G 381 mm / 15 in
I 711 mm / 28 in
J 330 mm / 13 in
MAXIMUM ALCOVE DEPTH 1220 MM / 48 IN.
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
DO NOT REMOVE THIS LABEL
254
REPORT NO: 219-S-04-2
FLOOR
PROTECTION*
K 457 mm / 18 in
L 150 mm / 6 in
M 150 mm / 6 in
* In Canada, ß oor protection must extend 18"
(457mm) to the front and 8" (200mm) to each
side and back of the stove.
IF SIDE LOAD DOOR IS USED:
Floor protection must extend 18" (457mm) from
the side of the unit to the wall.
Floor protection must be a minimum of 3/8" thick
with a minimum k factor of 0.84.
Minimum clearance with side load door in use is
18" (457mm) to side wall or refer to dimension
(A) if side load door is not used.
MANUFACTURED BY:
FPI FIREPLACE PRODUCTS INTERNATIONAL
LTD.
6988 VENTURE ST.
DELTA, BC V4G 1H4
CERTIFIED TO COMPLY WITH JULY 1990
PARTICULATE EMISSION STANDARDS.
CAUTION
BACK
M
L
O
K
FRONT
MADE IN CANADA
918-216
rev. 09/05
Hampton H300 Cast Freestanding Woodstove