Connect The Cables To The Base - JVC TK-C205VP Instructions Manual

Hide thumbs Also See for TK-C205VP:
Table of Contents

Advertisement

Available languages

Available languages

Installation and connection

Connect the Cables to the Base

Connect the coaxial cables and power supply cable to the terminals within the Base.
• Turn OFF the power supply to all compornents before making connections.
Fold back the net and insulate so that a short cir-
cuit does not occur from the net coming apart.
Net
12mm
15
(
/
"
)
32
• If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur
when the unit is at its maximum power consumption. Either use a thick cable to restrict
the voltage drop at the camera side to below 10%, or place the power supply near to
the camera. If voltage drop occurs during operation, the performance will be unstable.
• Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.
• When using a DC 12 V power supply, ensure that the polarities of the cable are correct.
• The AC 24 V power supply should conform to the following:
U-type:
Class 2 only
E-type:
Isolated power supply only
E-12
Polyethylene
Core line
Insulation tape
5mm
3
(
/
"
)
16
DC 12 V or AC 24 V
Power Supply cable
Power Supply
terminal
Coaxial
cable
processing
terminal
Coaxial cable
Conductor diameter (mm)
Maximum
extension (m)
Video signal cables
Connect the coaxial cables to the coaxial
cable processing terminal.
• Use the RG-59 or RG-6 video signal
cable (coaxial cable).
• If RG-11 is used, the cable cannot be
directly connected to the terminal. Connect
the RG-6 coaxial cable to the terminal and
link to the RG-11 coaxial cable.
• Perform the process shown on the left
diagram (above illustration) for the coaxial
cable tip before connecting.
DC 12 V or AC 24 V power supply cable
Connect a DC 12V or AC 24V power supply
cable to the power supply terminal. To pre-
vent connection errors or a cable disconnec-
tion, we recommend the use of lug plates for
the connections.
The following table shows the connection dis-
tances and connection cables provided that
2-conductor VVF cables (vinyl-insulated vi-
nyl sheath cables) are used.
DC 12V
24V
Do not cross the power supply cable and
coaxial cable.
CAUTION
CAUTION
1.0mm
1.6mm
ø
ø
(AWG18) (AWG14) (AWG12)
60m
160m
(200ft)
(520ft)
150m
400m
(490ft)
(1300ft)
2.0mm
ø
250m
(820ft)A C
600m
(2000ft)