  • Page 1 ® HUAWEI Quidway R2600/3600 Series Modular Routers Installation Manual V200R001...
  • Page 2 The information in this document is subject to change without notice. Although every effort has been made to make this document as accurate, complete, and clear as possible, Huawei Technologies assumes no responsibility for any errors that may appear in this document.
  • Page 3 About This Manual Contents The manual consists of 8 chapters that brief the appearance, features, installation, configuration, maintenance, troubleshooting and function modules of Quidway R2600/3600 Series Modular Routers. Chapter 1 is a brief introduction of the Quidway R2600/3600 series modular routers.
  • Page 4 Conventions Used in the Document Keyboard operation Format Description <Key > Press the key with key name expressed with a pointed bracket, e.g. <Enter>, <Tab>, <Backspace>, or <A >. <Key 1 + Key 2> Press the keys concurrently; e.g. <Ctrl+Alt+A> means the three keys should be pressed concurrently.
  • Page 5: Table Of Contents

    Installation Manual Quidway R2600/3600 Series Modular Routers Table of Contents Table of Contents Chapter 1 Introduction ......................... 1-1 1.1 Quidway R2600/3600 Series Modular Routers ..............1-1 1.2 Models ..........................1-1 1.3 Function Modules Supported.................... 1-1 1.4 Product Features ......................1-2 1.5 Typical Application ......................
  • Page 6 Installation Manual Quidway R2600/3600 Series Modular Routers Table of Contents Chapter 4 Installation ........................4-1 4.1 Installation Flow ........................ 4-1 4.2 Mechanical Installation ..................... 4-1 4.2.1 Installing the Router in a Cabinet ................4-2 4.2.2 Installing the Router on Workbench............... 4-2 4.3 Power Connection......................
  • Page 7 Installation Manual Quidway R2600/3600 Series Modular Routers Table of Contents 8.3 Function Modules Installation ................... 8-3 8.4 Function Modules Troubleshooting................... 8-5 8.5 1FE/2FE Module ....................... 8-5 8.5.1 Introduction......................8-5 8.5.2 Appearance ......................8-6 8.5.3 Interface Attributes ....................8-7 8.5.4 Indicators on Panel ....................8-7 8.5.5 Interface Cable .......................
  • Page 8 Installation Manual Quidway R2600/3600 Series Modular Routers Table of Contents 8.10.4 Indicators on Panel .................... 8-48 8.10.5 Interface Cable ....................8-48 8.10.6 Connecting Interface Cable................8-49 8.11 2FXS/2FXO/2E&M Module................... 8-50 8.11.1 Introduction......................8-51 8.11.2 Appearance ......................8-51 8.11.3 Interface Attributes ..................... 8-51 8.11.4 Indicators on Panel ....................
  • Page 9: Chapter 1 Introduction

    1.1 Quidway R2600/3600 Series Modular Routers Quidway R2600/3600 series modular routers (referred to as R2600/3600 series hereafter) are independently developed by Huawei for enterprise networks. They can be used as core routers in medium- and small-sized Intranets, or as access servers at some major branch offices.
  • Page 10: Product Features

    Chapter 1 Installation Manual Quidway R2600/3600 Series Modular Routers Introduction 1-port 10/100Base-TX Fast Ethernet interface module (1FE) 2-port 10/100Base-TX Fast Ethernet interface module (2FE) 2-port high-speed sync/async serial interface module (2SA) 4-port high-speed sync/async serial interface module (4SA) 2-port sync/async serial interface+1 port ISDN BRI S/T interface module (2S1B) 1-port channelized cE1/PRI interface module (1E1) 2-port channelized cE1/PRI interface module (2E1) 4-port channelized cE1/PRI interface module (4E1)
  • Page 11: Typical Application

    Chapter 1 Installation Manual Quidway R2600/3600 Series Modular Routers Introduction V. Voice-related support features R2600/3600 series support voice features. It can provide the following voice module types for different users: 2FXS, 2FXO, 2E&M, 4FXS, 4FXO, 4E&M and E1VI, among which: 2FXS and 4FXS modules are used to connect analog phones.
  • Page 12 Chapter 1 Installation Manual Quidway R2600/3600 Series Modular Routers Introduction Quidway routers enterprise network solution Server Central network 办公 LAN 办公 办公 办公 Quidway 3680 Internet E1 trunk A8010 Refiner Phone DDN/FR Branch Intranet AT0/E&M Quidway R2600 3600 QuidwayR2600 3600 Branch Intranet PSTN/ PSTN/...
  • Page 13: Chapter 2 Appearance And System Features

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features Chapter 2 Appearance and System Features 2.1 Quidway R2620/R2621 2.1.1 Appearance I. Appearance of R2620 The front panel and rear panel of R2620 are shown in the following figures. SLOT0 SLOT1 WAN0 WAN1 LAN0 POWER...
  • Page 14: Indicators On Panel

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features 2.1.2 Indicators on Panel The meanings of indicators on the front panel of R2620/R2621 are shown in the following table. Table 2-1 Meanings of indicators on the front panel of R2620/R2621 Indicator Meaning POWER...
  • Page 15: Quidway R2630/R2630E

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features Table 2-3 System description of R2620/R2621 Item Description of R2620 Description of R2621 A maximum of 2 function modules can be configured according to Slot requirement. Power PC 8240 200MHz BOOT ROM 512KB 512KB...
  • Page 16: System Description

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features Table 2-4 Meanings of indicators on the front panel of R2630/R2630E Indicator Meaning POWER System power indicator: Off means power is off, On means power is on. Hardware status indicator.
  • Page 17: Quidway R2631/R2631E

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features 2.3 Quidway R2631/R2631E 2.3.1 Appearance For R2631 and R2631E, their front panels and rear panels are very similar, see their outlook as the following (take R2631 as an example). Figure 2-7 Front panel of R2631 Figure 2-8 Rear panel of R2631 2.3.2 Indicators on Panels...
  • Page 18: System Description

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features 2.3.3 System Description The following table shows the basic configuration, dimensions, operating environment, etc. of R2631 and R2631E. Table 2-9 System description of R2631/R2631E Item Description of R2631 Description of R2631E A maximum of 3 interface modules can be configured according to Slot...
  • Page 19: Indicators On Panel

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features Figure 2-10 Rear panel of R3640 2.4.2 Indicators on Panel The meanings of indicators on the front panel of R3640/R3640E are shown in the following table. Table 2-10 Meanings of indicators on the front panel of R3640/R3640E Indicator Meaning POWER...
  • Page 20: Quidway R3680/R3680E

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features Table 2-11 System Description of R3640/R3640E Item Description of R3640 Description of R3640E Slot A maximum of 4 function modules can be configured according to requirement. Processor Pentium 133MHz Power PC 8240 250MHz NVRAM...
  • Page 21: Indicators On Panel

    Chapter 2 Installation Manual Quidway R2600/3600 Series Modular Routers Appearance and System Features 2.5.2 Indicators on Panel The meanings of indicators on the front panel of R3680/R3680E are shown in the following table. Table 2-12 Meanings of indicators on the front panel of R3680/R3680E Indicator Meaning POWER...
  • Page 22: Chapter 3 Installation Preparations

    Chapter 3 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Preparations Chapter 3 Installation Preparations 3.1 Safety Recommendations Routers play the key role in data communications network. Please pay attention to the following: Warning: It indicates that this operation may seriously damage the router or endanger the operator.
  • Page 23: Cleanness Requirements

    Chapter 3 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Preparations Table 3-1 Humidity requirement in the equipment room Temperature Relative humidity Safety operating Safety operating Normal operating condition Normal operating condition condition condition C to 30 Cto 45 40% to 65% 10% to 90% Note: 1) The values of environmental temperature and humidity in the equipment room are measured at 1.5m...
  • Page 24: Esd-Preventive Requirements

    Chapter 3 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Preparations Table 3-3 Value limits for harmful gas contents in equipment room Average (mg/m Max. (mg/m 0.03 0.04 0.15 0.05 0.15 0.01 3.2.3 ESD-Preventive Requirements Although many antistatic considerations have been given to R2600/3600 series, damage to the router’s circuit or even the whole equipment may still happen when the static electricity exceeds the tolerance threshold.
  • Page 25: Workbench Requirements

    Chapter 3 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Preparations Ensure the shell of the chassis is well grounded through the ground wire. Ensure the neutral point of the socket of AC power supply is well grounded. To enhance the lightning protection capability of the power supply, a lightning arrester could be installed at the input end of the power supply.
  • Page 26: Chapter 4 Installation

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Chapter 4 Installation 4.1 Installation Flow Begin to install Preparation and confirmation Connect the router to the specified position Connect various cables Check after installation Power on Configure the router Installation completed Figure 4-1 Flow for installing R2600/3600 series routers Caution:...
  • Page 27: Installing The Router In A Cabinet

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Installing it in the cabinet Placing it on the workbench 4.2.1 Installing the Router in a Cabinet R2600/3600 series have been designed according to the size of the standard 19-inch cabinet, and their dimensions are respectively: Quidway R3680, R3680E: Width x height x depth = 440mm x 86mm x 400mm Quidway R2630, R2630E, R2631, R2631E, R3640, and R3640E:...
  • Page 28: Power Connection

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation 4.3 Power Connection 4.3.1 Connecting Power Cable R2600/3600 series support the AC/DC power modules (See Chapter 2 Appearance and System Features). You can select different types of power modules according to the specific environment where the router is used.
  • Page 29 Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Step 1: Connect one end of the ground cable on the chassis accompanying the router to the ground pin on the router’s rear panel, and well ground the other end. Step 2: After confirming the power switch of the router is turned off, connect one end of the power line accompanying the router to the power input socket on the router’s rear panel, and connect the other end to the AC socket that delivered with the router.
  • Page 30: Connecting Ground Cable

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Step 4: Check that the power indicator in the rear panel of the router is on. It is on when the power cable is correctly connected. 4.3.2 Connecting Ground Cable Warning: The normal connection of the router’s ground cable is the primary guarantee for the anti-lightning and anti-interference capability of the router, so you must connect the ground cable carefully.
  • Page 31: Connecting Console Port

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation 4.4.1 Connecting Console Port I. Introduction to console R2600/3600 series provide a console in compliance with the EIA/TIA-232 asynchronous serial standard, through which the user can implement the local configuration of the router. II.
  • Page 32: Connecting Aux Port

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Table 4-2 Console cable pinouts RJ-45 Signal Direction DB-25 DB-9 ---> ---> ---> <--- <--- <--- IV. Connecting console cable While configuring the router at the configuration terminal, connect the console cable in the following steps: Step 1: Plug the console cable’s DB-9 (or DB-25) connector to the serial interface in the PC or the terminal where the router is to be configured.
  • Page 33 Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation III. AUX cable The AUX cable is an 8-core shielded cable. One end of it has a RJ-45 connector adopting RS-232 standard, which is to be connected to AUX. The DB-25-pin and DB- 9-pin connector of the other end are plugged with the DB-25-pin or DB-9-pin socket in Modem according to the actual requirements.
  • Page 34: Connecting Interface Cable

    Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Set up a remote configuration environment MODEM Serial interface cable MODEM Telephone cable PSTN MODEM 660000 Quidway R3640 AUX cable Figure 4-10 Setting up remote configuration environment via the AUX interface Caution: Console and AUX cannot be used at the same time.
  • Page 35 Chapter 4 Installation Manual Quidway R2600/3600 Series Modular Routers Installation Caution: It is very important to check after the router has been installed. For the normal operation of the router is directly affected by following factors: whether the router is mounted firmly, whether it is well grounded, and whether it uses proper power supply.
  • Page 36: Chapter 5 Startup And Configuration

    Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration Chapter 5 Startup and Configuration 5.1 Starting the Router If R2600/3600 series are installed and used for the first time, you can only configure through the console port. 5.1.1 Setting up Configuration Environment Set up a local configuration environment...
  • Page 37 Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration Set the Windows 98 HyperTerminal parameters as follows: In the HyperTerminal window shown in Figure 5-2, click on the <Property> button, and a HyperTerminal dialog box will pop up as shown in Figure 5-3. Select the serial interface for connection in [Connect To] in the HyperTerminal property dialog box.
  • Page 38 Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration Figure 5-3 HyperTerminal property dialog box Figure 5-4 Setting serial interface parameters...
  • Page 39: Powering On Router

    Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration Figure 5-5 Setting terminal type III. Power on the router After making sure that the router and the configuration terminal are correctly connected and having completed the setting of configuration terminal parameters, you can power on the router.
  • Page 40: Starting Router

    Be aware that the BOOTROM terminals of different versions may have slightly different interfaces. Quidway starts booting ****************************************** Quidway Series Router Boot Rom, V4.10 ****************************************** Copyright(C) 1999-2001 by Huawei Technologies Co., Ltd. Now Testing Memory...OK! 64M bytes DRAM 8192K bytes flash memory Press Ctrl-B to enter Boot Menu ..
  • Page 41: Configuring Router Via Setup

    Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration II. Initializing the system If the router is powered on, the router will start self-check. When self-check is completed, the terminal screen will display: Press ENTER key to get start when you see ATS0=1 System now is starting ...ATS0=1 Press <Enter>...
  • Page 42 Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration II. Displaying the interface status Firstly, would you like to see the current interface summary? [yes]:y Interface IP-Address Status Protocol Ethernet0 129.102.100.141 down Serial0 down Serial1 down Serial2 down III.
  • Page 43: Configuration Basic

    Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration no shutdown no ip address no ipx network VI. Confirming the configuration Use this configuration? [yes/no]: Now writing the configuration to flash memory. Write the running config to flash memory successfully. Please reboot the router.
  • Page 44: Help

    Chapter 5 Installation Manual Quidway R2600/3600 Series Modular Routers Startup and Configuration 5.2.2 Help R2600/3600 series provide a rich set of online help: In any command mode, enter <help> for a brief description for the related help. In any command mode, enter <?> for all the commands in this mode and a brief description about the command.
  • Page 45: Chapter 6 Maintenance

    Note: Different versions of BOOTROM may have slightly different interfaces at the terminal. Quidway start booting ****************************************** Quidway Series Router Boot Rom, V4.10 * ****************************************** Copyright(C) 1999-2001 by Huawei Technologies CO., LTD. Now Testing Memory...OK! 64M bytes DRAM 8192K bytes flash memory Press Ctrl-B to enter Boot Menu ..
  • Page 46: Upgrading Software Via Xmodem

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Note: In order to access the BOOT menu, you shall press <Ctrl+B> within a few seconds after the information “Press Ctrl-B to enter Boot Menu...” appears; otherwise the system will enter the program decompression process.
  • Page 47 Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Note: After the terminal baud rate is modified, it is necessary to disconnect and then re-connect the terminal, so as to effect the new setting. Step 4: Select [Transfer\Transfer File] from the terminal window, and the following dialog box will be popped up.
  • Page 48: Upgrading Main Program Via Tftp

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Please waiting, it needs a long time (about 1 min). Write Flash Success. Please return to 9600 bps. Press ENTER key to reboot the system. II. Upgrading BOOTROM Step 1: Attach a terminal or a PC (For a PC, it is necessary to run a terminal emulation program) to the console of the router.
  • Page 49 Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Caution: TFTP Server program is not supplied together with R2600/3600 series and should be prepared by the user. Step 3: Run the terminal emulation program on the PC connected to the console, and boot the router.
  • Page 50: Uploading And Downloading Files Via Ftp

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance The loading is successful. Press <Enter>, and the router will be rebooted. Caution: Please do not upgrade the software system of the router rashly. If necessary, upgrade under the guidance of technical support engineer.
  • Page 51 Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance II. Uploading configuration file Configure the Ethernet interface address of the router to connect the host running the FTP client program to the router. Log in the FTP server with the username and password already set in the router. Take the FTP client program provided by Windows 98 as an example: With the DOS prompt, enter <FTP A.B.C.D>...
  • Page 52: Password Lost

    <quit> to exit the client program. 6.1.5 Password Lost If you have lost the BOOTROM password or privileged user password for accessing the router, please contact the technical support personnel of Huawei. 6.2 Hardware Maintenance Caution: Before this operation, switch off the power to channel ESD voltages; otherwise, the operator may be prone to electric shock.
  • Page 53: Opening The Chassis

    2) There is a seal of Huawei on a screw in the cover of R2600/3600 series. The seal shall not be opened before the maintenance of the router. So first contact the local agent of Huawei for permission before opening the cover of the router, or perform operations according to the relevant regulation of the local agent.
  • Page 54: Replacing The Simm

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance II. Open the chassis Caution: Before this operation, switch off the power to channel ESD voltages; otherwise, the operator may be prone to electric shock. Follow the steps below to open the chassis: Step 1: Turn off the power of the router.
  • Page 55 Maintenance In case of upgrading VRP (Versatile Routing Platform, a software platform independently developed by Huawei), it’s necessary to expand memory. If a large number of routing tables are maintained in the router, or there are some tasks demanding huge memory, it’s necessary to expand memory.
  • Page 56 Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Figure 6-5a Location of BOOTROM and SIMM on system card (for R2630/2631/3640/3680) Figure 6-5b Location of BOOTROM and SDRAM SIMM on system card (for R2630E/2631E/3640E/3680E) 6-12...
  • Page 57 Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Figure 6-5c Location of BOOTROM and SDRAM SIMM on system card (for R2620/R2621) To install the SIMMs correctly, there are two bumps In the SIMM slot matching two concave points in the SIMM. II.
  • Page 58: Replacing Bootrom

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Step 4: Hold the non-conductive edge of the SIMM with your thumb and index finger, pull it out of the slot, and put it into a static shielding bag. Step 5: Repeat Step 2 to 4 until all the SIMMs are removed. Caution: 1) You can only hold the non-conductive edge of the SIMM, which is prone to static damage due to improper operation.
  • Page 59 Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance II. Determining the BOOTROM location on the main board Please refer to Figure 6-5. III. Replacing BOOTROM Step 1: Wear an ESD-preventive wrist strap, and make sure that one end of it well contacts your skin, and the other end is connected to the ground.
  • Page 60: Closing The Chassis

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance Caution: 1) Make sure to align the edge of the socket with that of BOOTROM. Wrong installation direction may lead to damage to BOOTROM and socket. 2) Before closing the chassis when you have replaced the necessary components, make sure that all the cables inside the router are combed tidily.
  • Page 61: Replacing The Function Modules

    Chapter 6 Installation Manual Quidway R2600/3600 Series Modular Routers Maintenance 6.2.5 Replacing the Function Modules Refer to Chapter 8 Function Modules. 6-17...
  • Page 62: Chapter 7 Troubleshooting

    If the power required by the router matches the power supplied. Caution: If the POWER indicator is still off after checking the above items, please contact the local agent of Huawei. Never plug or unplug the power cable with the system being powered on.
  • Page 63: Chapter 8 Function Modules

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Chapter 8 Function Modules 8.1 Introduction to Function Modules R2600/3600 series support the following interface modules: 1-port 10/100Base-TX Fast Ethernet interface module (1FE) 2-port 10/100Base-TX Fast Ethernet interface module (2FE) 2-port high-speed sync/async serial interface module (2SA) 4-port high-speed sync/async serial interface module (4SA) 2-port sync/async serial interface +1-port ISDN BRI S/T interface module (2S1B)
  • Page 64 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules WAN1 WAN0 CONSOLE SLOT0 SLOT1 Figure 8-2 Arrangement of the R2621 slots S lo t 1 S lo t 2 S lo t 0 Figure 8-3 Arrangement of the R2630/2630E slots S lo t 2 S lo t 1 S lo t 0...
  • Page 65: Function Modules Installation

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Slot 7 Slot 5 Slot 6 Slot 4 Slot 3 Slot 1 Slot 2 Slot 0 Figure 8-6 Arrangement of the R3680/3680E slots 8.3 Function Modules Installation Before installing the function modules, please carefully read Chapter 3 Installation Preparations.
  • Page 66 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Step 1: Place the router with the rear panel forward. Step 2: Hold the interface unit, and align its corner with the edge of the opening in the rear panel at the bottom of the router, as shown in Figure 8-7. Step 3: Push the interface unit to the inside of the router until it presses against the rear panel of the router, as shown in Figure 8-7.
  • Page 67: Function Modules Troubleshooting

    After installing the function module, power on the router to check the status of READY indicator. It is on when the module completes self-check and works normally. It is off when the module fails to pass self-check, please contact the local agent of Huawei. If the function module of R2600/3600 series works abnormally, please: Check that the cable selected for the interface is correct.
  • Page 68: Appearance

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules The FE interface can work at the speed of 100Mbps or 10Mbps, and can implement auto-sensing. The FE interface can work in full-duplex or half-duplex mode; the former is more commonly used.
  • Page 69: Interface Attributes

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-10 Appearance of 2FE 8.5.3 Interface Attributes Table 8-1 Attributes of 1FE/2FE Attribute Connector RJ-45 Number of interfaces Ethernet_II Ethernet_SNAP Frame formats supported IEEE 802.2 IEEE 802.3 Network protocols supported Novell IPX 8.5.4 Indicators on Panel I.
  • Page 70: Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-2 Meanings of indicators of 1FE Indicator Meaning LINK Off means the Ethernet link is not connected. On means the link is connected. Off means no data is being received or transmitted on the Ethernet interface. Blinking ACTIVE means data is being received or transmitted.
  • Page 71 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-4 RJ-45 pinouts RJ-45 pin Signal Description of signal Send data (+) Send data (-) Receive data (+) Receive data (-) II. Preparing Ethernet cable The following figure illustrates how to use Category 5 twisted pair to prepare the Ethernet cable with a RJ-45 connector.
  • Page 72: Connecting Interface Cable

    It is on when the module has completed self-check and works normally. It is off when the module fails to pass the self-check, and please contact the local agent of Huawei. Step 3: After powering on the system, please check the status of the LINK indicator of FE.
  • Page 73: 2Sa/4Sa Module

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.6 2SA/4SA Module Warning: Plugging or unplugging the interface cable of 2SA/4SA module is prohibited when the router is powered on, otherwise, the equipment or the module may be damaged. 8.6.1 Introduction Caution: Before connecting the sync/async serial interface, please make sure of the following:...
  • Page 74 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules III. Introduction to DTE and DCE 2SA/4SA are usually connected to Modem. When they are used as dialup ports, it is necessary to set their baud rates. The synchronous serial interface can work in either DTE mode or DCE mode. Two devices directly connected should work in DTE and DCE modes respectively.
  • Page 75: Appearance

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-7 Baud rate and transmission distance for V.35 cable Baud rate (bps) Maximum transmission distance (meter) 2400 1250 4800 9600 19200 38400 56000 64000 2048000 8.6.2 Appearance I. Appearance of 2SA module The appearance of the 2SA module is shown in the following figure: Figure 8-17 Appearance of 2SA II.
  • Page 76: Interface Attributes

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.6.3 Interface Attributes I. Interface attributes of 2SA module The interface attributes of the 2SA module are given in the following table: Table 8-8 Interface attributes of 2SA Description Attribute Synchronous Asynchronous...
  • Page 77: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-9 Interface attributes of 4SA Description Attribute Synchronous Asynchronous Connector DB-100 DB-100 Interface V.24 V.35 X.21 EIA/TIA-449 EIA-530 standard and EIA/TIA-232 operating mode Minimum baud 1200 1200 1200 rate (bps) Maximum baud 2.048M...
  • Page 78: Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules II. Indicators on Panel of 4SA The front panel of 4SA is shown as follows: Figure 8-20 Front panel of 4SA The meanings of the indicators on 4SA are given in the following table: Table 8-11 Meanings of indicators of 4SA Indicator Meaning...
  • Page 79 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Enlarged A side Enlarged B side Pos.1 Pos.25 DB50 Male DB25 Male Label Pos.50 Pos.1 Figure 8-21 EIA-232 (V.24) DTE cable Table 8-12 EIA/TIA-232 DTE cable pinouts (DB-50↔DB-25) DB-50 Signal Description Direction...
  • Page 80 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Enlarged B side Enlarged A side Pos.1 Pos.1 Db50 Male DB25 Female Label Pos.50 Pos.25 Figure 8-22 EIA-232 (V.24) DCE cable Table 8-13 EIA/TIA-232 DCE cable pinouts (DB-50 ↔ DB-25) DB-50 Signal Description...
  • Page 81 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Enlarged B side Pos.50 Enlarged A side V.35 Male D B50 Male Label Pos.1 Figure 8-23 V.35 DTE cable Table 8-14 V.35 DTE cable pinouts (DB-50↔ 34PIN) DB-50 Signal Description Direction 34 PIN...
  • Page 82 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Note: The pins not referenced in the above table are not connected. V.35 DCE Enlarged A side Female Enlarged B side Pos.50 V.35 Female DB50 Male Label Pos.1 Figure 8-24 Cable connection via V.35 DCE 8-20...
  • Page 83 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-15 V.35 DCE cable pinouts (DB-50 ↔34PIN) DB-50 Signal Description Direction 34 PIN Signal CTS/RTS Twisted pair no. 8 → RTS/CTS Twisted pair no. 9 → → DTR/DSR Twisted pair no.
  • Page 84: Connecting Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-25 Interface cable for 4SA module 4SA module provides 1-to-4 conversion cables. One end of the cables is connected to the DB-100 connector of 4SA module, and the other end is connected to the line connection cable.
  • Page 85 It is on when the module has completed self-check and works normally. It is off when the module fails to pass the self-check. In this case, please contact the local agent of Huawei. Step 4: Power on the router, and check the status of the LINK indicator on the front panel of 4SA.
  • Page 86: 8As/16As Module

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.7 8AS/16AS Module Warning: Plugging or unplugging the interface cable of the 8AS/16AS module is prohibited when the router is powered on, otherwise the equipment or the module may be damaged. 8.7.1 Introduction I.
  • Page 87: Appearance

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules For example, an 8AS is plugged to slots 1 and 4 of the Quidway R3680 series respectively. Then the 8-port asynchronous serial interfaces in slot 1 are numbered from Async0 to Async7, and those in slot 4 are numbered from Async8 to Async15. 8.7.2 Appearance I.
  • Page 88: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-16 Interface attributes of 8AS/16AS Attribute 16AS Connector DB-68 DB-200 Interface standard and operating EIA/TIA-232 mode Minimum baud rate (bps) Maximum baud rate (bps) 115.2k ---Dialup through Modem ---Backup Service supported ---Terminal access service...
  • Page 89: Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Each channel in 16AS has only one indicator. It is on when the link is connected, and it blinks when the link is active (i.e., receiving and transmitting data). 8.7.5 Interface Cable I.
  • Page 90 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-18 8AS cable pinouts Serial No DB-25 network end DB-9 network end Signal 68 PIN SCSI router end 8-28...
  • Page 91 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Serial No DB-25 network end DB-9 network end Signal 68 PIN SCSI router end Note: The pins not referenced in the above table are not connected. II. Interface cable of 16AS Caution: This cable is selected for the 16-port asynchronous interface module.
  • Page 92 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Based on the above figure, the following table describes the 16AS cable pinouts: Table 8-19 16AS cable pinouts Serial No DB-25 network end DB-9 network end Signal 200 PIN SCSI router end 8-30...
  • Page 93 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Serial No DB-25 network end DB-9 network end Signal 200 PIN SCSI router end 8-31...
  • Page 94: Connecting Interface Cable

    It is on when the module has completed self-check and works normally. It is off when the module fails to pass the self-check. In this case, please contact the local agent of Huawei. Step 4: Power on the system and check the states of the indicators on the front panels...
  • Page 95: 1E1/2E1/4E1 Module

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules LINK indicator of 8AS is on when the line is connected, and off when the link is disconnected. LINK indicator of 16AS is on when the line is connected, and off when the line is disconnected.
  • Page 96: Appearance

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules In the same interface unit, the order for the interface numbers is the same as that for the numbers on the module. For example, in the Quidway R3680, plug a 4E1 into slot 1 and a 2E1 into slot 3. The four cE1/PRI interfaces in slot 1 are numbered from Controller E1 0 to Controller E1 3, and the two cE1/PRI interfaces in slot 3 are numbered from Controller E1 4 to Controller E1 5.
  • Page 97: Interface Attributes

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules III. Appearance of 4E1 module The appearance of 4E1 is shown in the following figure: Figure 8-34 Appearance of 4E1 8.8.3 Interface Attributes The interface attributes of cE1/PRI are shown in the following table: Table 8-20 Interface attributes of 1E1/2E1/4E1 Attribute 1-channel cE1/PRI(1E1)
  • Page 98: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.8.4 Indicators on Panel The front panel of 1E1 is shown as follows: Figure 8-35 Front panel of 1E1 The meanings of the indicators on 1E1 are given in the following table: Table 8-21 Meanings of the indicators of 1E1 Indicator Meaning...
  • Page 99: Interface Cable

    DB15 Male BNC connector Label Cable tie Magnetic core HUAWEI Hot-shrinkable tube Pos.15 Figure 8-38 1E1/2E1 module cables If a cable with the impedance being 120-ohm is needed, it can be realized by the 75- ohm-to-120-ohm cable converter (one end is BNC and the other end is RJ-45 connector) shown as follows.
  • Page 100 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-24 E1 G.703 cable pinouts cE1/PRI end Network end DB-15 RJ-45 Signal Signal Signal Tx Tip Tx Tip Rx Tip Tx Ring Tx Ring Rx Ring Tx Shield Rx Shield Rx Tip Rx Tip...
  • Page 101: Internal Dip Switches

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-25 4E1 cable pinouts DB-25 Signal Direction of signal DB-15 Signal Remark TxR4 → TxRing RxSD4 RxShield RxT4 ← RxTip Channel 3 → TxT4 TxTip TxSD4 TxShield RxR4 ←...
  • Page 102 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-27 Corresponding relations between DIP switches and E1 interfaces (4E1 module) DIP switch Corresponding E1 interface Interface 0 Interface 1 Interface 2 Interface 3 The following figure shows how to use DIP switches to set the default impedance of 1E1/2E1/4E1 module interface cable as 75-ohm.
  • Page 103: Connecting Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-28 Configuration of 1E1/2E1/4E1 DIP switches Configuration method Function description Connected to 75-ohm unbalanced coaxial cable ( DB-15 to BNC) 1, 2, 3, 4 Connected to 120-ohm balanced twisted pair cable 5: ON 6: ON...
  • Page 104 It is off when the module fails to pass the self-check. In this case, please contact the local agent of Huawei. Step 5: Power on the system and check the status of LINK indicator of 4E1. It is off when the line is faulty and signal is out of synchronization.
  • Page 105: 4Bs Module

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.9 4BS Module Caution: If the ISDN BRI S/T interface cable of 4BS module is led out to the outdoor, a special lightning arrester should be installed at the input end of the signal line to obtain better lightning protection effect. 8.9.1 Introduction I.
  • Page 106: Interface Attributes

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-43 Appearance of 4BS 8.9.3 Interface Attributes I. Interface attributes of 4BS The interface attributes of 4BS are shown in the following figure: Table 8-29 Interface attributes of 4BS Attribute Description Interface...
  • Page 107: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-44 DIP switch of 4BS Table 8-30 Configuration of 4BS DIP switch Digit Setting method Corresponding channel Description of function 100-ohm matched resistance used 1 and 2 Channel 0 100-ohm matched resistance not used 100-ohm matched resistance used 3 and 4...
  • Page 108: Interface Cable

    It is on when the module has completed self-check and works normally. It is off when the module fails to pass the self-check. In this case, please contact the local agent of Huawei. Caution: When connecting the cables, observe the identifiers on the interfaces to avoid wrong connection and damage to the module and the router.
  • Page 109: Appearance

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 2S1B can be used in R2600/3600 series. It is mainly responsible for receiving, transmitting and processing the data streams on the 2-channel sync/async serial interface and the 1-channel ISDN BRI S/T interface. The ISDN BRI S/T interface can work in dialup mode and leased line mode.
  • Page 110: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Note: An external adapter is necessary for X.21, EIA/TIA-449, and EIA-530. Table 8-33 Attributes of ISDN BRI S/T interface of 2S1B Attribute Description Connector RJ-45 Number of interfaces ---ISDN dialup Operating mode ---ISDN leased line ---ISDN...
  • Page 111: Connecting Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Before connecting to the sync/async serial interface, confirm the line properties. There are four optional cables depending on different line properties. V.35 DCE cable V.35 DTE cable V.24 DCE cable V.24 DTE cable One end of the cables is connected to the router side via the DB-50 connector, and the connection of the other end of the cables is varied with the network side to which it is...
  • Page 112: 2Fxs/2Fxo/2E&M Module

    It is on when the BRI interface of the module has completed self-check, and is working normally. It is off when the BRI interface of the module fails to pass self-check. In this case, please contact the local agent of Huawei. Caution: When connecting the cables, observe the identifiers on the interfaces to avoid wrong connection and damage to the module and the router.
  • Page 113: Introduction

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.11.1 Introduction 2FXS/2FXO/2E&M can be used in R2600/3600 series. It is mainly responsible for processing the 2-channel analog voice signal and transmitting the voice signal over the data communication network. 2FXS (2-port analog subscriber) module provides ordinary analog telephone access.
  • Page 114: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-35 Interface attributes of 2FXS/2FXO/2E&M Attribute Description Connector RJ-45 Number of attributes ---User circuit interface (2FXS): Q.512 compliant. ---Ring trunk interface (2FXO): Q.552 compliant. Interface standards ---E&M trunk interface (2E&M): G.712 compliant; E&M interface (Bell type I, II, III and V).
  • Page 115: Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.11.5 Interface Cable The external interface of 2FXS/2FXO/2E&M is a standard RJ-45 connector. The cable for 2FXS/2FXO is a standard analog telephone cable, both ends of which are RJ-11 connectors. The cable for 2E&M needs to be selected according to the type of switch to be connected.
  • Page 116 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-52 Sequence of RJ-45 pinouts When using Bell V 4-wire mode of connection, the corresponding relationship of RJ-45 pinouts at router side and at the switch side is shown as the following figure. Router on-hook off-hook...
  • Page 117: Connecting Interface Cable

    If they are off after the system is powered on, this indicates that the module fails to pass the self-check. In this case, please contact the local agent of Huawei. Caution: When connecting the cables, observe the identification marks on the interfaces to avoid wrong connection and damage to the module and the router’s host.
  • Page 118: 4Fxs/4Fxo/4E&M Module

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.12 4FXS/4FXO/4E&M Module Caution: 4FXS/4FXO module is equipped with an interface cable which has a toroidal magnetic core at one end. To ensure the electromagnetic compatibility of the whole router, please connect the end with the toroidal magnetic core to the router.
  • Page 119: Interface Attributes

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-54 Appearance of 4FXS/4FXO/4E&M 8.12.3 Interface Attributes The interface attributes of 4FXS/4FXO/4E&M are shown in the following table: Table 8-39 Interface attributes of 4FXS/4FXO/4E&M Attribute Description Connector RJ-45 Number of interfaces ---Subscriber circuit interface (4FXS): Q.512 compliant ---Ring trunk interface (4FXO): Q.552.
  • Page 120: Interface Cable

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Figure 8-57 Front panel of 4E&M The meanings of the indicators on 4FSX/4FXO/4E&M are shown in the following table: Table 8-40 Meanings of the indicators of 4FXS/4FXO/4E&M Indicator Meaning Yellow lamp Off means the channel is idle.
  • Page 121: 8Lsa Module

    If they are off after the system is powered on, this indicates that the module fails to pass the self-check. In this case, please contact the local agent of Huawei. Caution: When connecting the cables, observe the identification marks on the interfaces to avoid wrong connection and damage to the module and the router's host.
  • Page 122: Appearance

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Caution: Before connecting to the sync/async serial interface, make sure the following: 1) Type of the devices connected to the sync/async serial interface, i.e., if it is synchronous or asynchronous, if it works in DTE mode or DCE mode.
  • Page 123: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-41 Interface attributes of 8LSA Attribute Description Synchronous Asynchronous Connector DB-200 DB-200 V.24 V.35 Interface standard and EIA/TIA-232 operating mode Minimum baud rate (bps) 1200 1200 Maximum baud rate (bps) 128M 115.2K ---Dialup via Modem...
  • Page 124 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules V.24 DCE cable V.24 DTE cable One end of the cables is connected to the router side via the DB-200 connector, and the connection of the other end of the cables is varied with the network side to which it is connected.
  • Page 125 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules P: Path Figure 8-61 8LSA interface cable pinouts (V.24 DCE) II. 8LSA interface cable pinouts (V.24 DTE) DB25 male connector Figure 8-62 8LSA interface cable (V.24 DTE) 8-63...
  • Page 126 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules P: Path Figure 8-63 8LSA interface cable pinouts (V.24 DTE) III. 8LSA interface cable pinouts (V.35 DCE) Figure 8-64 8LSA interface cable (V.35 DCE) 8-64...
  • Page 127 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules P: Path Figure 8-65 8LSA interface cable pinouts (V.35 DCE) IV. 8LSA interface cable pinouts (V.35 DTE) Figure 8-66 8LSA interface cable (V.35 DTE) 8-65...
  • Page 128: Connecting Interface Cable

    If the indicator is Off, it means module has failed self-test. In this case, please contact the local agent of Huawei. Step 4: Power on the router and check the status of LINK indicator of 8LSA. It is Off when fault has occurred to the line and signal is out of synchronization.
  • Page 129: E1Vi Module

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules 8.14 E1VI Module Caution: If the interface cable of E1V1 module is led out to the outdoor, a special lightning arrester should be installed at the input end of the signal line to obtain better lightning protection effect. 8.14.1 Introduction E1VI module is developed for meeting the requirements of processing dense voice signals in VoIP system.
  • Page 130: Indicators On Panel

    Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Table 8-43 Attributes of E1VI Attribute E1 Voice Signal Connector DB-15 Number of interfaces ---E1 Frame formats supported ---CE1 ---ISDN PRI ---R2 signaling ---ITU-T compression algorithm G.711, G.723, G.729 Services supported ---H.323 ---ISDN PRI...
  • Page 131 Chapter 8 Installation Manual Quidway R2600/3600 Series Modular Routers Function Modules Caution: The E1V1 module cables are optional, and make sure that you have selected the necessary cables when purchasing the E1V1 module. E1VI interface cable is a G.703-compliant 120-ohm cable. Its router end is a DB-15 male connector, and its network end is RJ-45 connector.
  • Page 132: Connecting Interface Cable

    If the indicator is Off, it means module has failed self-test. In this case, please contact the local agent of Huawei. Step 4: Power on the router and check the status of LINK indicator of E1VI. It is Off when fault has occurred to the line and signal is out of synchronization.
  • Page 133 How Are We Doing Let us share your comments with respect to the contents, formats and wording of this manual. Your feedback can be of great value in helping us improve our document. Please +86-755-6540035 use a copy of these two pages for your comments, and fax to: Documentation Development Department.
  • Page 134 4. Feel free to write any comments below or on an attached sheet. 5. It is highly appreciated for any specific mistakes you have found (this page may be sent to us separately). Page & Mistake Suggested Correction Line No. If we may contact you concerning your comments, please complete the following: Name:______________________ Tel: _____________________________ Company:________________________________ Date:________________...

This manual is also suitable for:

Quidway 3600 seriesQuidway r3600 series

Table of Contents