Location Requirements - Maytag UXT5330ADS0 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

Parts needed
For direct wire installation
UL listed or CSA approved 1/2"(12.5 mm) strain relief
2 - 75-watt max incandescent
light bulbs
or
1 - 75-watt max and 1 - 25-watt max incandescent
light bulb
(for use as a night light)
Power supply cable (if needed, for direct wire installation)
For power supply cord installation
UL Listed Power Supply Cord Connection
Kit marked for
range hood use.
2 - 75-watt max incandescent
light bulbs
or
1 - 75-watt max and 1 - 25-watt max incandescent
light bulb
(for use as a night light)
For vented installations you also need:
31/4"x 10" (8.3 x 25.4 cm) or 6" (15.2 cm) or larger round metal
venting
6" (15.2 cm) or larger round damper, if using 6" (15.2 cm) or
larger round vent system
31/4"x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter
transition piece
For cabinets with recessed bottoms:
Two 2" (5.1 cm) wide filler strips. Length and thickness
determined by recess dimensions.
Four flat head wood screws or machine screws with washers
and nuts (to attach filler strips).
IMPORTANT." Observe all governing codes and ordinances.
It is the installer's responsibility
to comply with installation
clearances specified on the model/serial rating plate. The
model/serial
rating plate is located inside the range hood on
the left wall.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions
provide minimum clearance. Consult the
cooktop/range
manufacturer installation instructions
before
making any cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements"
section.
The hood is factory-set
for vented installations. For non-
vented (recirculating) installations,
charcoal filter pad Part
Number 4396390 is available. See the "Assistance
or
Service" section for information
on ordering.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured
Home Construction
Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction
and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured
Home
Installation 1982 (Manufactured
Home Sites, Communities
and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
11/2"
12"
_(3.8
ore)
(30.5
era)
9,,
(2.5 crn)
9"
(22.9 cm)
29 %" (75.9cm) - 30"(76.2cm)model
20"
(44.5cm)
35 %"
(91.t cm) - 36" (91.4 cm) mod_
Installation Clearances
opemnc
I
24" (61.0 cm) rain.
30" (76.2 cm)
suggested
max.
bottom
of cabinet
g surface
18" (45.7 cm)
rain. clearance
upper cabinet
to countertop
36" (91.4 cm)