Installation Requirements; Tools And Parts; Location Requirements - Maytag 99043751D Installation Instructions And Use And Care Manual

30" (76.2 cm) and 36" (91.4 cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Drill
1 " (3 cm) drill bit
" (3 mm) drill bit for pilot holes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof caulking compound
Flat-blade screwdriver
Phillips screwdriver
For vented installations, you also need:
Saber or keyhole saw
Compass or 6 " (15.9 cm) circle template (if using a 3¼" x
10" [8.3 x 25.4 cm] rectangular vent to 6" [15.2 cm] round
vent transition)
Vent clamps
Metal snips
Parts supplied
Remove parts from package. Check that all parts are included.
4 - #10 x
" type A truss Phillips screws
Filter
3 " x 10" (8.3 x 25.4 cm) vent connector/damper
2 - #8B sheet metal screws
Parts needed
For direct wire installation
UL listed or CSA approved
75-watt max. incandescent light bulb
Power supply cable (if needed, for direct wire installation)
For power supply cord installation
UL Listed Power Supply Cord Connection Kit marked for
range hood use.
75-watt max. incandescent light bulb
For vented installations, you also need:
3 " x 10" (8.3 x 25.4 cm) or 6" (15.2 cm) round metal venting
3 " x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) vent transition piece
if using 6" (15.2 cm) round venting.
For cabinets with recessed bottoms:
2 - 2" (5.1 cm) wide filler strips. Length and thickness
determined by recess dimensions.
4 flat-head wood screws or machine screws with washers
and nuts (to attach filler strips).
4

INSTALLATION REQUIREMENTS

" (12.5 mm) strain relief

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located inside the range hood on
the rear wall.
Range hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
All openings in ceiling and wall where range hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
1 "
(3.8 cm)
12"
(30.5 cm)
9"
(22.9 cm)
2"
(5.1 cm)
6"
(15.2 cm)
"
(1.9 cm)
7 "
(19.1 cm)
29 " (75.9 cm) - 30" (76.2 cm) model
35 " (91.1 cm) - 36" (91.4 cm) model
1"
(2.5 cm)
1 "
(3.8 cm)
"
(9.5 mm)
17 "
(44.5 cm)