Extra functions - Customer level 2

Hot water settings

Hot water peak
This function takes the domestic hot water temperature temporarily up to
approximately 65°C. Three settings are possible: inactive (default), daily or
preferred day. The function is used to help protect the end user from poten-
tially harmful bacteria, such as legionella.

Timer control

The menu for opening timer controls are as follows:
1. Press the Heat button until Access = CUSTOMER2 is displayed.
2. Press the Menu button.
3. Turn the menu dial clockwise until the menu Timer control settings (menu
4) is displayed.
4. Press the Select button and scroll through the menus using the menu dial.
Setting of the heat pump according to clock
The function Clock setting HP accord. to clock is for those who want the heat
pump to produce different amounts of heat at different times of the day and
on different days of the week. This allows further energy savings. The room
sensor T5 (GT5) infl uence is deactivated 2 hours after using clock setting for
the heating, or after any type of external control of the heat pump. This allows
the heating to return to ordinary settings.
Example:
In the event that the heat pump is required to maintain the radiator tempera-
ture 3°C lower on Mondays between 22:00 and 06:00.
1. Turn the dial clockwise until the menu Clock setting HP accord. to clock
(menu 4.1) is displayed.
2. Press the Select button.
3. Turn the menu dial clockwise to select the day. Now press the Adjust
button to select the weekday with the symbol ^. Turn the menu dial
clockwise one step to activate the start day. The weekday now has a capital
letter.
4. Press the right-hand arrow (->) until the cursor reaches the fi rst two zeros
(00).
22
Hot water setting
Interval for
hot water peak
2.2
Return
Select
Main menu
Indoor temperature
settings
1
Return
Select
Main menu
Timer control
settings
4
Return
Select
Note
When there are time based tariffs
with cheaper electricity for example
during the night, any savings may be
lost if the return to normal tempera-
ture occurs when the more expen-
sive electricity price applies.
Clock setting
Clock setting HP
accord. to clock 4.1
Return
Select
Clock setting HP 1
mo
00:00-00:00
Return
adjust
Clock setting HP 1
Mo
00:00-00:00
Return
->
Clock setting HP 1
Mo
00:00-00:00
Return
->

Advertisement

Table of Contents