System Parameters

Allows you to set parameters affecting the operation of the whole
system:

Cycle rate

Specifies how often the boiler will switch on and off in any given
hour. measured as cycles per hour. A typical cycle rate is 6
cycles per hour, giving a 10 minute cycle length.

Off temperature

Specifies the temperature that the system will revert to when the
system is turned off, for frost protection.

Holiday temperature

Specifies the temperature set throughout all zones when the
user selects Holiday mode:

Internal sensor offset

Specifies the offset of the internal sensor temperature, when the
unit is placed in a location where the measurement needs to be
corrected:
8

Min. boiler on time

Specifies a minimum on time for the heat source, to ensure all
the heat is dissipated from the system before shutting off.