Download Print this page

Technical Specifications - HP DL385 Quickspecs

Hp proliant generation 2 (g2)
Hide thumbs Also See for DL385:

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions (H x W x D)
Dimensions
Dimensions
Dimensions
(with bezel)
Weight
Weight
Weight
Weight
(approximate)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
(per power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
DA - 12565
North America — Version 41 — July 23, 2008
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/calc/Power%20
Calculator%20Catalog.xls
- Click on the system of interest. Example: DL385 G2
- Follow the instructions of the next screens.
Rated Steady-State Power 800 W (at 100 VAC),
Maximum Peak Power
Non-operating
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
HP ProLiant DL385 Generation 2 (G2)
60 lb (27.22 kg)
47.18 lb (20.41 kg)
100 VAC,
120VAC,
200-240 VAC
10 A (at 100 VAC),
9 A (at 120 VAC),
6.1 A (at 200 VAC)
50 to 60 Hz
980 W (at 100 VAC),
1035 W (at 120 VAC),
1170 W (at 240 VAC)
3350 BTU/hr (at 100 VAC),
3530 BTU/hr (at 120 VAC),
3990 BTU/hr (at 240 VAC)
850 W (at 120 VAC),
1000 W (at 200-240 VAC)
800 W (at 100 VAC),
850 W (at 120 VAC),
1000 W (at 200-240 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Page 42