Download Print this page

HP Integrity rx2660 Quickspecs page 21

Hp integrity server
Hide thumbs Also See for Integrity rx2660:

Advertisement

QuickSpecs
Technical Specifications
Maximum I/O Cards
Maximum I/O Cards
Maximum I/O Cards
Maximum I/O Cards
(See supported I/O table
for product specifics)
Electrical Characteristics
Electrical Characteristics
Electrical Characteristics
Electrical Characteristics
Site Preparation
Site Preparation
Site Preparation
Site Preparation
Environmental
Environmental
Environmental
Environmental
Characteristics
Characteristics
Characteristics
Characteristics
Mass Storage
Mass Storage
Mass Storage
Mass Storage
LAN
LAN
LAN
LAN
WAN
WAN
WAN
WAN
Multi-Function
Multi-Function
Multi-Function (Mass Storage / LAN)
Multi-Function
Additional Interface Cards
Additional Interface Cards
Additional Interface Cards
Additional Interface Cards
AC Input power
AC Input power
AC Input power
AC Input power
Hot swap Power supplies
Hot swap Power supplies
Hot swap Power supplies
Hot swap Power supplies
Redundant AC power inputs
Redundant AC power inputs
Redundant AC power inputs
Redundant AC power inputs
Maximum input power
Maximum input power (for maximum processor,
Maximum input power
Maximum input power
memory, disk, DVD, I/O configurations)
Input Power at Idle (for maximum processor,
Input Power at Idle
Input Power at Idle
Input Power at Idle
memory, disk, DVD, I/O configurations)
Maximum input current
Maximum input current
Maximum input current
Maximum input current
Power factor at full load
Power factor at full load
Power factor at full load
Power factor at full load
Site planning and installation included
Site planning and installation included
Site planning and installation included
Site planning and installation included
NOTE:
NOTE:
NOTE:
NOTE: System is customer installable.
Rack depth
Rack depth
Rack depth
Rack depth (inches/mm)
Rack width
Rack width
Rack width (inches/mm)
Rack width
Rack height
Rack height
Rack height (EIA/inches/mm)
Rack height
Rack weight
Rack weight
Rack weight
Rack weight (kg/lbs) maximum
Regulatory Model
Regulatory Model
Regulatory Model
Regulatory Model
Acoustics
Acoustics
Acoustics (operator/bystander) at at at at 77° F (25° C)
Acoustics
Operating Temperature
Operating Temperature
Operating Temperature
Operating Temperature
(up to 5000 ft/1524
m)*
Non-operating Temperature
Non-operating Temperature
Non-operating Temperature
Non-operating Temperature
Maximum rate of temperature change
Maximum rate of temperature change
Maximum rate of temperature change
Maximum rate of temperature change
Operating relative humidity
Operating relative humidity
Operating relative humidity
Operating relative humidity
Non-operating relative humidity
Non-operating relative humidity
Non-operating relative humidity
Non-operating relative humidity
Operating altitude above sea level
Operating altitude above sea level
Operating altitude above sea level
Operating altitude above sea level
Non-operating altitude above sea level
Non-operating altitude above sea level
Non-operating altitude above sea level
Non-operating altitude above sea level
* Maximum operating temperature range up to 5000 feet. For higher altitudes, de-rate the maximum
temperature by 2°C/1000 feet above 5000 feet.
DA - 12698
Worldwide — Version 30 — April 13, 2012
3
3
3
3
3
100-240V 50/60 Hz
1 included, 2nd for N+1
1 included, 2nd for N+1
798W
2,724 BTU/hour
567W
1,936 BTU/hour
10A @ 100 Vms or 7A @ 200 Vms
0.98 (approximately)
No
26.8 in (680 mm)
19 in (482 mm)
2U/ 3.4 in (86 mm)
61.6 lbs. (28 kg)
RSVL 0503
77° F (25° C)
77° F (25° C)
77° F (25° C)
7.0 Bels LwA
41° to 95° F (5° to 35° C)
5° to 35° F (-40° to 70° C)
20° C/hour
15% to 80% RH non-condensing
8% to 85% non-condensing
10,000 ft (3,000 m) maximum
15,000 ft (4,600 m) maximum
HP Integrity rx2660 Server
HP Integrity rx2660 Server
HP Integrity rx2660 Server
HP Integrity rx2660 Server
Page 21

Advertisement

loading