First Alert ReadyGuard-R User Manual page 26

Hide thumbs Also See for ReadyGuard-R:
Table of Contents

Advertisement

Scheduling User Interface
Entry
Event
0
Empty
1
X-10 Device
2
Latch Key Report
3
Automatic Stay Arming
4
Reminder Announcements
5
Alarm Clock
Event Identifier Entries
No event scheduled (or schedule is temporarily disabled)
Turn an X-10 device, either on or off at begin/end times. (will
have a start and end time to program) (time driven)
SH10A siren cannot be used.
Note:
Send a special pager report (7110000) indicating system not
yet disarmed. (will have a start/end time to send the report)
(window driven), (reports only to pager)
Notes: Option *49 must be programmed to be 6 or higher.
Make sure unit is armed prior to start of window time.
Will arm the system automatically, and bypass any open
zones, at a given time. It will send a report to the pager and
central station, indicating system has been auto armed stay,
plus all bypass reports. (will have only a start time to send the
report) (time driven)
Notes: (1) Prior executing auto stay arming, force bypass will
be executed - if option *23 was enabled.
(2) If pager report is required, Option *49 must be
programmed to be 6 or higher.
Will beep three times and then announce custom words 72,
73 and 74. This will be repeated every minute until a key is
depressed, or a button type zone does an arm or disarm.
Note: Make sure installer programmed custom words 72-74
at the time of installation.
Will start a trouble tone on the speaker, which will continue
until a key is depressed.
Figure 1.