ReadyGuard-RI is not intended for UL985 Household Fire applications unless a 24-hour backup battery
U U U U L L L L
(P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable ReadyGuard-RI quickly and easily by providing the
basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to
the ReadyGuard-RI Installation and Setup Guide.
The following steps assume that one of the system's default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone
2
front door
3
back door
4
window
5
motion detector
6
-------
7
-------
8
-------
9
-------
26
loop 3 arm away
27
loop 2 disarm
28
loop 4 arm stay
29
loop 1 no alarm response
30
loop 3 arm away
31
loop 2 disarm
32
loop 4 arm stay
33
loop 1 no alarm response
92
99
Master User Code
Installer Code
Duress Code
Entering Expert Program Mode: installer code + 8 0 0
Interactive Mode
* 56 Enhanced Zone Programming
* 83 Enhanced Sequential Mode
*84 Assign Zone Voice Descriptors
Exiting Program Mode: * 98 inhibits re-entry into the Programming mode using the Installer Code.
* 99 allows re-entry into the Program mode using Installer Code + 8 0 0.
NOTES:
• Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed
as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.
• Primary and secondary report format for all tables is Ademco's Contact ID® reporting.
• Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log.
Table 1
front door
back door
garage door
motion detector
smoke detector
-------
-------
-------
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 no alarm response
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 no alarm response
duress
silent alarm
audible alarm
1-2-3-4
4-1-1-2
------
ReadyGuard-RI
Security Systems
Table 2
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
duress
silent alarm
1-2-3-4
4-1-1-2
------
Used to Program
Zone characteristics, report codes, and serial numbers
5800 Series transmitter serial numbers
Voice descriptors for each zone
K14117-1
Quick Start Guide
Table 3
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
duress
silent alarm
1-2-3-4
4-1-1-2
------
4/06 Rev. A
Table 4
duress
1-2-3-4
4-1-1-2
------
Need help?
Do you have a question about the ReadyGuard-RI and is the answer not in the manual?
Questions and answers