ReadyGuard-R and ReadyGuard-REN are not intended for UL985 Household Fire applications unless a 24-
hour backup battery (P/N LYNXRCHKIT-HC) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable ReadyGuard-R and ReadyGuard-REN quickly and easily by
providing the basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to
the ReadyGuard-R Series Installation Instructions.
The following steps assume that one of the system's default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the Installation
Instructions.
Default Table Summary
Zone
1
-------
2
front door
3
back door
4
window
5
motion detector
6
-------
7
-------
8
-------
9
-------
26
loop 3 arm away
27
loop 2 disarm
28
loop 4 arm stay
29
loop 1 restore device 1
30
loop 3 arm away
31
loop 2 disarm
32
loop 4 arm stay
33
loop 1 restore device 1
92
99
Master User Code
Installer Code
Duress Code
Entering Program Mode: Installer Code + 8 0 0
Interactive Mode
56 Enhanced Zone Programming
83 Enhanced Sequential Mode
84 Assign Zone Voice Descriptors
Exiting Program Mode: ✻ 99 allows re-entry into the Program mode using Installer Code + 8 0 0.
✻ 98 inhibits re-entry into the Programming mode using the Installer Code.
NOTES: • Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline
Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For
other applications or actions (e.g., using a pulsing siren), see the ✻80 Device Programming Menu Mode section of the
Installation Instructions.
• Primary report format for all tables is Ademco's Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary
reporting. Tables 1, and 3 use 4+1 format for secondary reporting.
• Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores
in their event logs.
Table 1
-------
front door
back door
garage door
motion detector
smoke detector
-------
-------
-------
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 restore device 1
duress
silent alarm
audible alarm
1-2-3-4
4-1-1-2
------
5HDG\*XDUG56HULHV
Table 2
-------
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
duress
silent alarm
1-2-3-4
4-1-1-2
------
Used to Program
Zone characteristics, report codes, and serial numbers
5800 Series transmitter serial numbers
Voice descriptors for each zone
K5966-1V1 10/03 Rev. A
Table 3
-------
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
duress
silent alarm
1-2-3-4
4-1-1-2
------
Table 4
duress
1-2-3-4
4-1-1-2
------

Advertisement

loading

Summary of Contents for First Alert ReadyGuard-R Series

  • Page 1 This Quick Start Guide can help you install the rechargeable ReadyGuard-R and ReadyGuard-REN quickly and easily by providing the basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to the ReadyGuard-R Series Installation Instructions. The following steps assume that one of the system’s default tables will be used.
  • Page 2 Installing ReadyGuard-R-Series Installation and Electrical Connections Step Action Install the control as follows: Separate the front assembly from the back plate and disconnect the cable from the front assembly board. Note: Disconnect the cable only from the front assembly board, not from the terminal block PC board . Mount the back plate.
  • Page 3: System Programming

    9VAC, 15VA BELL 2k OHMS 6-14VDC EOLR 30mA max. 6-14VDC 120mA max. (e.g. WAVE2EX) THE READYGUARD-R SERIES SYNC CONTROLS ARE EQUIPPED WITH WEEKLY TESTING IS AN INTEGRAL RECHARGEABLE REQUIRED TO ENSURE BATTERY PACK PROPER OPERATION P/N LYNXRCHKIT-SC. OF THIS SYSTEM...
  • Page 4 Step Action ✻ Enhanced Sequential Mode - Press 83, then follow the prompts as follows: Zone Number - Enter 2-digit zone number of the first transmitter to have its serial number entered. The system will announce the Voice Descriptor for the selected zone number, if it is programmed.
  • Page 5 Step Action Manual Entry - Enter the 7-digit serial number printed on the transmitter. If you enter an (Cont.) incorrect digit, press the [#] key to backup to prompt (1A) and start over. When all seven digits ✻ are entered press the [ ] key.
  • Page 6 Keypad Functions (when default programming is used) Security Functions Checking system status: STATUS (high level messages); press STATUS again for secondary messages. To arm in STAY mode: Press and hold down STAY (or enter your code + STAY ) See note below. To restart exit delay: STAY (applies only if system is armed in Stay mode and Quick Exit option has been enabled) To arm in AWAY mode: Press and hold down AWAY (or enter your code + AWAY ) See note below.
  • Page 7 Remote Phone Control Operation To remotely disarm system: + [1] To remotely arm in AWAY mode: + [2] To remotely arm in STAY mode: + [3] To remotely arm in AWAY or STAY with NO DELAY: + [2] or [3] + [0] To remotely activate X-10 devices 1-6: [#] + [4] + device no.
  • Page 8 165 Eileen Way, Syosset, New York 11791 http://www.firstalertpro.com Copyright  2003 Honeywell International Inc. i.9£l K5966-1V1 10/03 Rev. A...

This manual is also suitable for:

Readyguard-rReadyguard-ren