Installation
Instructions
Electrical
connection
(non-Canada)
o 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
.
2.
.
.
.
.
Turn off power supply to outlet.
Remove the screw securing the terminal block
access cover in the lower corner on the back of
the dryer.
Install a UL-approved
strain relief according
to the power cord/strain relief manufacturer's
instructions
in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 10-30 type SRDT, through the
strain relief.
Attach the power cord neutral (center wire)
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely.
Attach the remaining two power cord outer
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws securely.
___
Install
...........
UL-approved
................
_/
strain relief hem
Terminal screw
recovery slot
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
.
Follow manufacturer's
guidelines for firmly
securing the strain relief and power cord.
8.
Reinstall the terminal block cover.