Leveling The Range - GE JGSP23 Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Installation Instructions
Leveling the Range
Checking
Range
the
For proper baking results, the range must be leveled.
The height of the range must also be adjusted
to the
height of the counter.
To do this:
1. Install the oven racks (see cleaning sections of the Use and Care Manual for instructions and additional
information).
2. Use a 1 3/8" open end or adjustable
wrench to equally back out the four leg levelers
until the flanges
(rims) on the sides of the cooktop
are above the top of the counter.
3. Place range where
it will be installed.
Put a spirit level or glass measuring
cup partially filled with water on
one of the open racks.
4. Use the wrench
to adjust the leg levelers.
Spirit
Level
Leeg_e
_lp_
L°nW;er
Range
38" Cabinet Installation
Adjusting the height of the range to match that of the cabinet height
The height of the range must be adjusted to the countertop
height. For countertop
heights greater
than 37",
additional
measurements
may need to be taken as detailed
below.
When the range is elevated to the maximum
height, there is a large space between
the bottom of the
range and the floor, referred to as the toe space. This may be visually
objectionable.
The legs should not
be extended
any further than to provide a maximum
of 3"
toe space.
I_'
J
Y'
J
_
"
'
The.n eisdesi nedto r
lair a
at the bottom of the range.
(Example:
When legs are
screwed
all the way into the base rail),
t 1"Min.Height
This gap is very important
to the proper ventilation
of the range and must be maintained
when treating the
appearance
of the toe space.
The following
is a suggested
method
of making a filler for the toe space when the legs are extended
as
mentioned
before.
After the range is installed with the longer legs and is in position
and level, measure
from the bottom of the bodyside
to the floor.
This will be the required
height of the toe space filler. This height
may range from 2 1/16" to 3". Any height less than 2 1/16" may not
be visually objectionable
and not need the filler.
Build the filler as shown.
Make sure to provide the 3/4" gap at the
top and the 5/16" gap at the bottom.
These gaps will provide
the
proper ventilation
as mentioned
before.
If you wish to attach the filler to the floor or adjacent
cabinets,
use
screws or other removable
fasteners,
so that the range can be
readily removed
if necessary.
I li_
Gusset
corners
II ]1 I_------"_....-..--.""IF---_
with
3/4" to 1"
II
II _
H_Triangular
or
_.-JJ II H
_1_
square
Stock
_'--................_
_
._----'JI
3/4"
21,1,..to
3"as . _J-_,
Required
or as {",L-,."_16"_-/--/-
I_,_,,,'_L_'-t _
30"
required
to recess_'t__
behind
toe area of)
Use 1/4" to 1/2" material
adjacent
cabinets
finished
to match toe area
of cabinets
12