STEP 3
INSTALL ANTI-TIP DEVICE
• All ranges can tip.
• BURNSor other SERIOUSINJURIES
can result.
INSTALLand CHECKthe ANTI-TIP
bracket following these instructions.
To reduce the risk of tipping the range, the range must
be secured bg a properlg installed anti-tip bracket. See
installation instructions shipped with the bracket
for complete details before attempting to install.
To check if the bracket is installed and engaged properly,
look underneath the range. The anti-tip bracket should be
inserted into the opening on the anti-tip brace on the
range. If the bracket arm misses the brace to the left or
right, or the bracket arm is not protruding through the
brace opening, the bracket must be reinstalled.
If the range is pulled from the wall for ang reason, alwags
repeat this procedure to verify the range is properly
secured bg the anti-tip bracket.
If gour range has no anti-tip bracket, call 1.800.626.8774
to receive one at no cost.
If the anti-tip device supplied with the range does not fit this
application, use the universal Anti-Tip Device WB2X7909.
Read the AHAP1Anti-Tip Safety Brochure packed with
the bracket.
Anti-Tip
Parts Provided
4 WoodScrews
Anti-TipBracket
3 HexHeadScrews
(2 required,1 extra)
Anti-TipBrace
AHAM Anti-Tip
Safety Brochure
• Attach the anti-tip brace onto the bottom of the
range in the recessed area. Install 2 hex screws
(provided) through
the brace and into the range.
NOTE: This anti-tip
device mag be installed on the
opposite side of the range.
HexScrews
Anti-TipBrace
AlternateBrace
Position
• Measure and mark Dimension A (see table below)
from the left (or right) side of the installation
location. If the countertop
has an overhang,
add that dimension
to Dimension A.
• Place the anti-tip
bracket against the floor and
back wall at the marked location. Mark screw holes
for fastening
the bracket to the wall sole plate and
the floor.
• Drill 1/8" pilot holes at a 20 ° angle.
• Secure the bracket to the wall and/or
floor with
at least 2 wood screws (provided).
For Concrete
or Cement Construction:
You must
use appropriate
fastening
hardware
(not provided).
Range
A
Anti-Tip Bracket
30"
5-1/16"
!
36"
5-1/16"
Wall SolePlate
/
48"
8-1/4"