Installation Preparation
4-WIRE POWER CORD INSTALLATION
NOTE: A 4-wire cord is connected
to the range
at the factory.
Use the following
steps to change
an existing installation
from a 3-wire cord back
to a 4-wire cord.
- WARNING
The neutral
wire of the supplg circuit
must
be connected
to the neutral
terminal
located
in the lower center of the terminal
block.
The power leads must be connected
to the lower left and the lower right
terminals
of the terminal
block. The 4th
grounding
lead must be connected
to
the frame of the range with the ground
plate and the ground screw.
• Remove the 3 lower terminal
screws from
the terminal
block. Remove the ground screw
and ground plate and retain them.
• Remove the ground
strap. DO NOT DISCARD
THE GROUND STRAP OR ANY SCREWS.
• Insert the one ground screw into the power cord
ground wire terminal
ring, through
the ground
plate and into the frame of the range.
• Insert the 3 terminal screws (removed earlier)
through
each power cord terminal
ring and
into the lower terminals
of the terminal
block.
Be certain that the center wire (white/neutral)
is connected
to the center lower position
of the terminal
block. Tighten screws securely
into the terminal
block.
GroundStrap
Terminal
or
Block
GroundStrap
Neutral
Terminal
After
NeutralTerminal
Terminal
Block
Ground
Screw
GroundPlate
(grounding to
range)
3-WIRE POWER CORD INSTALLATION
NOTE: A 4-wire cord is connected
to the range
at the factorg. Use the following
steps to change
the range to a 3-wire cord.
WARNING
The neutral or ground wire of the power cord
must be connected to the neutral terminal
located
in the center of the terminal
block. The power leads
must be connected to the lower left and the lower
right terminals
of the terminal
block.
• Remove the ground strap (located at the right
side of the terminal
block) and connect
between
the center lower portion of the terminal
block
to the frame of the range.
• Remove the 3 lower terminal
screws from
the terminal block. Insert the 3 terminal screws
through
each power cord terminal ring and
into the lower terminals of the terminal
block.
Be certain that the center wire (white/neutral)
is connected
to the center lower position
of the terminal block. Tighten screws securelg
into the terminal
block.
DO NOT remove the ground
strap connection.
Terminal Block
aearance
mayvary)
Plate
Neutral
Terminal
Ground
Strap
10