Design Guide
THE INSTALLATION
SPACE
The
finished
cutout
width
must be
35d/2".
84-1/2" max
83-1/2"min
Finished
T
35-1/2"
_FinishedWidth_
10" _'_ Electrical
Area
¢
24" CutoutDepth
11/2"
3 1/2_
Wall View
74-1/2" From
Floorto Bottom
of Electrical
Water
And Electrical
Locations
Electrical
and water supply must be located
as shown.
The cutout
depth
must be 24"
Designed
for industry
standard
flush installation.
The
refrigerator
will project
forward,
slightly
beyond
adjacent
cabinetry,
depending
on your installation.
Cutout
depth beneath
a soffit:
When
installed
beneath
a soffit, the soffit cannot
exceed
the 24" installation
depth
shown.
The
top case
trim
overlaps
the bottom
of the soffit.
Additional
Specifications
, A 115 volt 60Hz.,
15 or 20 amp
power
supply
is
required.
An individual
properly
grounded
branch
circuit
or circuit
breaker
is recommended.
Install
a
properly
grounded
3-prong
electrical
receptacle
recessed
into the back wall. Electrical
must
be
located
on rear wall as shown.
Note:
GFI (ground
fault interrupter)
is not
recommended.
• Water
line can enter
the opening
through
the floor
or back wall. The water
line should
be 1/4"
O.D.
copper
tubing
between
the cold water line and
water connection
location,
long enough
to extend
to the front
of the refrigerator.
Installation
of an
easily accessible
shut off valve in the water line is
recommended.
38"
CaseWidth
DIMENSIONS
AND
CLEARANCES
* Shippingheight, The
*84" From refrigeratorcanbe adjusted
Floorto
to fit into a cutoutthat is
Top Frame 83-1/2"min, to 84-1/2"max,
height. Notethat the top case
trim at the front is 1/2" higher
andwill overlapupper
cabinetryor soffit. Use
leveling legsandwheels for
heightadjustment.
Frameto Frame
Width
Product
Clearances
These
refrigerators
are equipped
with a 2 position
door stop. The
factory
set 130 ° door
swing can be
adjusted
to 90 ° if clearance
to adjacent
cabinets
or
walls is restricted.
130 ° Door Swing
25"_
Minimum
, to Wall
I
\\
,k k,
X
X, k,
X
X,
X,
\,\\,\\
130° .......
..Y
90° Door Swing
Behind
il
'Fr3ia me
i
ii
-3/4"
'S
90°.........
Allow 25" minimum
clearance
for a full
4" Minimum
130 ° door
swing. Allow 15" for pan
removal,
to Wall
4" minimum
clearance
is required
when door swing
is adjusted to 90 °. If the 90 ° door stop position is
used, pan access is maintained,
but pan removal is
restricted.
See
illustrations
pages
4 and
5 to determine
door
swing
interaction
with
adjacent
cabinets
or
countertops.
ZUG2, ZUGSS2 Unified Grille Panel Kit
, If you are installing
two refrigerators,
side by side,
the installation
space must be "/1-1/2" wide.
Note: Additional cutout width may be required when side panels
are used. Add side panel thickness to the finished cutout to
calculate rough-in width.
• The water and electrical
locations
for each product
must be located as shown.
• A separate
l15V, 60Hz.,
15 or 20 amp power supply
is recommended
for each product.
q_
71d/2" Finished W idth
84q/2"max
83q/2"min
Finished
2-5/16"
i
_Electrical
_
_
24-3/16"
IF7"
: IFT'
18"
10"
L 24"Cutout
Depth
Opening
5) WaterSupply
i
_
26"_
_
26"_
3-1/2"
Wall View
74-112" From
F[{)or to Bottom
of [[ectrical
M/2"
3

Advertisement

Table of Contents
loading