Ductwork, Wiring Locations; Step 1, Install Framing For Hood Support - GE Monogram ZV830 Installation Instructions Manual

30" chimney vent hood
Hide thumbs Also See for Monogram ZV830:
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
INSTALLATION--VENTED
TO THE OUTSIDE
DUCTWORK,
WIRING LOCATIONS
Determine the exact location of the vent hood.
• Locate the template packed with the literature.
- Measure 36" from the floor to the top of the cooking
surface. Add hood installation height determined on
page 7. Mark that location.
- Use a level to draw a straight pencil line on the wall.
5-1/2" centerline to wall--_-
FOR CEILING VENT DUCTING
5-1/2" _
j15-1/2"
/_
Wallvent
House Wiring
t.,_-
\ L
Ceiling
27-3/4"min
Locat
on
,,
_8-1/2"
dla. hole
.... above
"_
................. installation
height
yy
IVn.
Instellotlon He_qht
AJlgnBottom EdgeWith
Pencillinelndlcotlng
Bottom of Hood
Align
Bottom
edgeWith
PendJ Line
Indlceting
Bottom
of Hood
r
- Tape the template in position along the penciled
line. CHECK TO BE SURE THE TEMPLATEIS LEVEL.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
• Use a level to draw a line straight up, from
the centerline on the template to the ceiling.
• Measure 5-1/2" from the buck wall to the centerline
of an 8-1/2" hole on the ceiling.
NOTE: If drywall is not present, add drywall thickness
to the 5-1/2" dimension.
Well Ducting:
If ductwork will vent to the rear:
• Use a level to draw a line straight up from
the centerline on the template.
• Measure at least 27-3/4" above the pencil line
that indicates the bottom installation height, to the
centerline of an 8-1/2" dia. duct hole. (Hole mag
be elongated for duct elbow.)
HOUSE WIRING LOCATION:
• The junction box is located on the top left side
of the hood.
• Wiring should enter the back wall at least 18" above
the bottom of the hood, and within 5-1/2" of the left
side of the centerline.
INSTALL FRAMING
FOR HOOD SUPPORT
IM PORTANT-
Freming
must be
cepeble
of supporting
100 Ibs.
8-1,
min. opening for ductwork
Centerline of
installation
space
View from rear
cleats
1" x 6" min.
mounting
support
If drgwall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
• Cut awag enough drgwall to expose 2 vertical studs
at the bracket location indicated on the template.
• Install a horizontal support at least 1" x 6"
between two wall studs at the mounting screw
location. The horizontel support must be flush with
the room side of the studs. Use cleats behind both
sides of the support to secure to wall studs.
IMPORTANT: Reinstall drgwall for an even mounting
surface.