STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
• Use a level to draw the cooktop centerline location.
Draw the line to ceiling height.
• Measure desired distance from the bottom of the hood
to the cooking surface, 30" min. to 36" max.
Note: If you are installing the hood with duct covers, be sure to read
"Using Duct Cover Accessories" page 7. Exact installation height
may be determined by use of one or more duct covers.
• Use a level to draw a straight horizontal pencil line
indicating the bottom of the hood.
• From the line indicating the bottom of the hood,
measure 15-3/8" up and draw another line for the
location of the wood support. See illustration.
FOR VERTICAL (Straight Up) DUCTING:
• Use a level to draw a centerline from the bottom of
the hood to ceiling or soffit.
• If venting out the ceiling, extend the centerline
forward on the ceiling or soffit.
• Locate the centerline of a 10-1/2" hole on the ceiling
or soffit by measuring 6" from the wall.

House Wiring Location:

• The junction box is fastened to the back of the hood
on the right side.
8-3/8"
Electrical
18-13/16" for 48" Models
Area
12-13/16" for 36" Models
9-13/16" for 30" Models
• The recessed back side of the hood provides a large
area for the house wiring to exit the wall and be
routed to the rear knockout and junction box.
• The location for the house wiring depends on the
installation height of the hood and the width of the
hood.
• Remove junction box cover and knockout. Install
strain relief.
Installation Instructions
Top of Hood
Wood
Support
15-3/8"
Bottom of Hood
FOR DUCTING THROUGH REAR WALL:
• Measure 9-7/8" above the marked line for the top of
the hood. At the centerline, mark location for a 10-1/2"
diameter hole.
Alternate Knockout Locations
If the installation requires, the junction box can be
relocated from the back to the top of the hood. Remove
3 screws, align box to top knockout and secure with
original screws.
• Remove junction box cover and knockout. Install strain
relief.
10
9-7/8"
18"
18"
*House Wiring
Location
*Depending on
Hood width and
Installation Height.
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
6-1/2"