Installation Preparation
DETERMINE INSTALLATION
HEIGHT
• Decorative duct covers are provided to conceal
the ductwork
running to the ceiling.
• This hood can be installed for recirculating
operation.
No kits required.
The hood installation
height, from the cooking
surface to the bottom
of the hood, depends upon
ceiling height.
For optimum
performance,
the hood must be 24"
min. and 30" max. above the cooking surface.
Use the chart on this page to accuratelg
determine
installation
height and support frame adjustment,
and to select the correct size top trim piece (A, B, C
or D).
DLa_
_
_
_I
BL_
AL_
,_
ZX92510
Accessorg
Duct cover
includes
a 36-3/4"
long
duct
cover
and 3 sets of duct
cover
top
trim
pieces
labeled
E, F, G.
Ceiling
Height
7'11"
8'
8'1"
8'1"
8' 2"
8'2"
8'3"
8'3"
8'4"
8'5"
8'5"
8' 6"
8'6"
8'7"
8'7"
8'8"
8'9"
8'9"
8' i0"
8' 10"
8'11"
8'11"
9'
Possible
Hood
Installation
Height (inches)
26
27
24
28
25
29
26
30
27
24
28
25
29
26
30
27
24
28
25
29
26
30
27
Mounting
Frame
Height (inches)
30 1/2
30 1/2
34 1/2
30 1/2
34 1/2
30 1/2
34 1/2
30 1/2
34 1/2
38 1/2
34 1/2
38 1/2
34 1/2
38 1/2
34 1/2
38 1/2
42 1/2
38 1/2
42 1/2
38 1/2
42 1/2
38 1/2
42 1/2
Trim Piece
Needed
A
A
B
A
B
A
B
A
B
C
B
C
B
C
B
C
D
C
D
C
D
C
D
9' 1"
24
46 1/2
E
9' 1"
28
42 1/2
D
9' 2"
25
46 1/2
E
9' 2"
29
42 1/2
D
9' 3"
26
46 1/2
E
9' 3"
30
42 1/2
D
9' 4"
27
46 1/2
E
9' 5"
24
50 1/2
F
9' 5"
28
46 1/2
E
9' 6"
25
50 1/2
F
9' 6"
29
46 1/2
E
9' 7"
26
50 1/2
F
9' 7"
30
46 1/2
E
9' 8"
27
50 1/2
F
9' 9"
24
54 1/2
G
9' 9"
28
SO 1/2
F
9' 10"
25
54 1/2
G
9' 10"
29
S0 1/2
F
9' 11"
26
54 1/2
G
9' 11"
30
50 1/2
F
10'
27
54 1/2
G
10' 1"
28
54 1/2
G

Advertisement