Advance Planning
ADVANCE PLANNING
Ductwork
Planning
• These vent hoods are equipped for 8" round
ductwork.
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest
duct route
possible. For satisfactory
performance,
duct run
should not exceed 100 ft. equivalent
length for any
duct configurations.
• Refer to "Duct Fittings" chart to compute the
maximum
permissible length for duct runs to
the outdoors.
• Use rigid metal ductwork only.
• Install a roof cap with damper at the exterior
opening. Order the cap and any transitions
needed
in advance.
Ceiling Framing for Adequate
Support
• These vent hoods are heavy. Adequate structural
support must be provided. The ceiling structure
must be capable of supporting
the weight of the
hood and any inadvertent
user contact loads
(approximately
200 pounds). The hood support
frame will be supported
by 2 x/4 cross framing.
• Installation will be easier if the vent hood is
installed before the cooktop or countertop
below
is installed.
Accessorg
Duct Cover
• All models are shipped with a duct cover for
ceiling heights of 7' 11" to 9'.
ZX92510 accessory
36-3/4"
duct cover is
available to reach 9' 1" to 10' 1" ceiling heights.
The accessory
should be ordered with the hood
and be on site before final framing
and wall
finishing.
POWER SUPPLY
IMPORTANT- (Please read carefully)
WARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE
MUST BE PROPERLYGROUNDED.
ATTENTION :POURDES
RAISONS DE SECURITE, CET APPAREIL
DOIT ETRE CORRECTEMENT
MIS A LA TERRE
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension
cord or adapter
plug with
this appliance.
Follow National electrical
codes or
prevailing
local codes and ordinances.
Electrical
Supplg
This vent hood must be supplied with 120V, 60Hz,
and connected
to an individual, properlg grounded
branch circuit, and protected
by a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
If the electrical supply does not meet the above
requirements,
call a licensed electrician
before
proceeding.
• Route house wiring in the ceiling, as close to the
installation
location as possible. Allow additional
length from ceiling joists to reach the junction
box on the bottom of the hood support frame.
• Connect the wiring to the house wiring in
accordance
with local codes.
Grounding
Instructions
The grounding
conductor
must be connected
to
a ground metal, permanent
wiring system, or an
equipment-grounding
terminal
or lead on the hood.
WARNING:
The improper
connection
of equipment-grounding
conductor
can result in a risk of electric
shock. Check with a qualified
electrician
or service
representative
if you are in doubt whether the
appliance
is properly grounded.
AVERTISSEMENT :
Le mauvais branchement
du fil de mise
la terre peut causer un choc @lectrique.
En cas de doute, consultez un 61ectricien qualifi@
ou un technicien
pour d6terminer
si I'appareil est
5 laterre.