Power Supply - GE Monogram ZVB36 Installation Instructions Manual

36", 30" downdraft vent systems
Hide thumbs Also See for Monogram ZVB36:
Table of Contents

Advertisement

mnstaliation
Preparation
POWER SUPPLY
Do Not Locate Gasor Electrical
Connections Within Shaded Area
FOR PERSONAL
SAFETY:
Remove house fuse or open
circuit breaker before beginning
instaflation.
Do not use an extension cord or
adapter plug with this appliance. Follow National
electrical
codes or prevailing local codes and ordi-
nances.
for 36"
28-1/2" for 30" Models
Outlet
12" Above
Cabinet Floor
Enlever le fusible ou d_clencher le
disjoncteur du panneau de la
maison avant de commencer
FinstaIBtion,
Ne pas utiliser de rallonge ni d'adaptateur de prise de
courant avec cet appareil, II faut respecter les codes
nationaux de I'_lectricit_
et les r_gbmentations
ou
codes Iocaux,
This downdraft vent must be supplied with 120V, 60Hz.,
and connected to an individual, properly grounded
branch circuit, protected by a 15 or 20 ampere circuit
breaker or time delay fuse.
Gas Cooktops
If this vent is installed in combination with a
Monogram gas cooktop, it may operate from the same
duplex outlet.
Electric
Ceoktops
If this vent is installed in combination with a
Monogram electric cooktop, the vent must operate
from a separate 120V outlet.
IMPORTANT
(Please read carefully).
The power cord of this appliance is equipped with a
three-prong
(grounding} plug which mates with a
standard three-prong
grounding wall receptacle to
minimize the possibility of electric shock. The
customer should have the wall receptacle
and
circuit checked by a qualified electrician to make
sure the receptacle
is properly grounded and has
correct polarity.
• Where a standard two-prong wall receptacle
is
encountered,
it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong
wall receptacle.
Do not, under any circumstances,
cut or
remove
the third (ground)
prong from the
power
cord.
DO NOT USE AN EXTENSION CORD.
• A properly grounded 3-prong receptacle should be
located within reach of the vents' two foot power
cord.
Locate the receptacle inside the cabinet on the right
side wall. The receptacle
cannot be placed on the
back of the cabinet wall where it may interfere with
the downdraft plenum. See illustration.
10